High Sensitive Displacement Transducer

CDP-M Small Displacement Transducer 5 to 100mmCE

The CDP-M is a small and high sensitive displacement transducer. Compared with conventional CDP series, its output is the same but its diameter is less by 50 - 20% than that of CDP, and its temperature range is extended up to +80°C. The CDP-M with cable output along the measurement axis and the CDP-MT with cable output vertical to the axis are available. The transducer can be used not only for static measurement but also for quasi-dynamic measurement. A fixing holder is supplied as a standard accessory. Options include ordinary magnet stand MB-B and small MB-PSL specified for the CDP-M series.

Protection rantings : IP 40 equivalent

CDP-M Small Displacement Transducer
Features
  • Compact
  • Easy handling
  • Allowable temperature range -10 to +80℃
  • Lineup of five models: 5 / 10 / 25 / 50 / 100 mm
  • High output of 10000 x 10-6 strain or more
  • CDP-5M/-10M Only CE Marking Compliant
  • Specifications

    Type Capacity Rated output Sensitivity
    (×10-6 strain/mm)
    Non-
    linearity
    Temperature
    range
    CDP-5M
    CDP-5MT
    5 mm 5 mV/V
    (10000x10-6 strain) ±0.3 %
    2000 0.3 %RO -10 to +80 ℃
     (no condensation)
    CDP-10M
    CDP-10MT
    10 mm 1000
    CDP-25M
    CDP-25MT
    25 mm 6.25 mV/V
    (12500x10-6 strain) ±0.3 %
    500
    CDP-50M
    CDP-50MT
    50 mm 5 mV/V
    (10000x10-6 strain) ±0.3 %
    200
    CDP-100M
    CDP-100MT
    100 mm 100

    Output polarity

    img-trout-01

    Measurement moves in the minus direction when the shaft is pushed inward.

CDP Displacement Transducer 5 to 100mmCE

The CDP is a compact and easy-to-operate displacement transducer. Because it is designed to produce a large output and to deliver stable performance, highly accurate measurements can be made. It is suitable for both static and dynamic measurements.

Protection ratings : IP 40 equivalent

高感度変位計 CDP
Features
  • High precision, High output
  • Excellent Response
  • Easy handling
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6 strain/mm)
    Non-
    linearity
    Temperature
    range
    CDP-5 5 mm 5 mV/V
    (10000x10-6 strain) ±0.1 %
    2000 0.15 %RO -10 to +60 ℃
     (no condensation)
    CDP-10 10 mm 5 mV/V
    (10000x10-6 strain) ±0.1 %
    1000 0.1%RO
    CDP-25 25 mm 6.25mV/V
    (12500x10-6 strain) ±0.1 %
    500
    CDP-50 50 mm 5mV/V
    (10000x10-6 strain) ±0.1 %
    200
    CDP-100 100 mm 100

    Output polarity

    img-trout-01-1

    Measurement moves in the minus direction when the shaft is pushed inward.

CDP-D Displacement Transducer with dual ports 50 to 100mm

The CDP-D displacement transducer is the CDP displacement transducer with dual isolated I/O ports. For example, one set of input and output cables can be connected to an analog measuring instrument and the other set to a digital measuring instrument. With two different types of measuring equipment connected to this transducer, simultaneous measurements can be made without interference.

Protection ratings : IP 40 equivalent

CDP-D Displacement Transducer with dual ports
Features
  • Measurement with two readout units
  • High precision, High output
  • Excellent response
  • Easy handling
  • Specifications

    Type Capacity Rated output Sensitivity
    (×10-6 strain/mm)
    Non-
    linearity
    Temperature
    range
    CDP-50-D 50 mm 5 mV/V
    (10000×10-6 strain)
    ±0.1 %
    200 0.1 %RO -10 to +60 ℃
    (no condensation)
    CDP-100-D 100 mm 100

    Output polarity

    img-trout-01_0

    Measurement moves in the minus direction when the shaft is pushed inward.

Pull-out type Displacement Transducer CDP-T 25mm

This is a displacement transducer having a spring force to draw the shaft inward the transducer body. It is based on our well-proven CDP type transducer, but its shaft is fully contracted by the spring force while the shaft of our ordinary CDP transducer is fully extended. A wire is hooked on the hook bolt mounted on the end of the shaft, and the shaft is pulled out by the wire. Displacement is measured as the movement of the shaft. Highly accurate measurement is possible owing to its large output and excellent stability.
(When using a wire for the displacement measurement, consider the loss of sensitivity caused by the elongation of the wire.)

Protection ratings: IP 40 equivalent

CDP-25T
Features
  • High accuracy and high output
  • Measurement possible in tensile direction
  • Easy handling
  • Specifications

    Type Capacity Rated output Sensitivity
    (×10-6strain/mm)
    Non-linearity Allowable temperature range
    CDP-25T 25mm 6.25mV/V
    (12500×10-6strain) ±0.15%
    500 0.15%RO -10~+60°C (no condensation)

    Output polarity

    img-trout-01t

    Measurement moves in the minus direction when the shaft is pushed inward.