High-speed, High-accuracy, High-functionality Data Logger/
High-accuracy, High-speed, Multi Point Measurement
High-accuracy / high-stability of measurement achieved with eliminated noise through our unique next generation A/D system
Measuring every 0.1 seconds with high-speed mode
Measurement of maximum 1,000 channels
Full range of monitor display functions
Real time checking of measured data updated every 0.1 seconds on the monitor display screen of T-ZACCS 9
Taking the advantage of the 9-inch wide screen, simultaneous display of maximum 60 measurement data
Selection of numeric monitor, MAX/MIN display, and graph display are provided to suit your purpose
Stress-free operability achieved through the improved processing speed and the renovated system configuration.
High-speed response communication control even when connected to a PC
Integrated with built-in 4 GB of memory, adopting an SD card as external recording media
Remote data logger function
Remote operation and downloading of recorded data files via web browser
Measuring/computing functions compatible with versatile measurements.
Integrated with versatile automatic measuring functions that include the interval measurement, comparator measurement, alarm measurement, sampling measurement, and sequence measurement
Integrating the extended channel function that permits real-time computing based on arbitrary computation formulas, and capable of executing versatile computations on the T-ZACCS 9
Measurement Box
High-accuracy, High-speed, Multi-Point Measurement
High-accuracy / high-stability of measurement achieved with eliminated noise through our unique next generation A/D system
Measuring every 0.1 seconds with high-speed mode
50 measuring points (maximum 1,000 measuring points when 20 boxes are connected)
Measurement Unit
High-accuracy, High-speed, Compact
10 channels excellent portability model
10 measuring points (maximum 1,000 measuring points when combined with the EX-50H)
Compatible with versatile sensors
Capable of measuring with strain gauges, strain gauge type converters, thermocouples, platinum resistance thermometers, and DC voltage
NDIS connector and terminal block are selectable as connectors
Digital Displacement Sensor Measurement Unit
Digital displacement sensors can be measured!
10-channel model with superior portability
10 measurement points (Maximum 1000 points can be measured in combination with EX-50H, etc.)
Digital Output Unit
Digital outputs based on trigger and alarm conditions
Digital signal output at TTL/LVTTL level based on trigger and alarm conditions set in T-ZACCS 9
Up to 10 non-isolated TTL or LVTTL level digital signal outputs
Easy connection via BNC cable
Analog Output Unit
Analog data output to suit the measuring data and computation results
Analog data output according to the measured data collected by the T-ZACCS 9 and the results of extended channel computation
10 analog output points (maximum 20 points of analog output when two units are connected)
Output range +/- 5 V, +/-10 V, 0/+5 V are selectable
Switching Box Protocol Converter
With EI-01P, ISW/IHW can be used with TS-960/-963!
Protocol converter for connecting the ISW-50G/IHW-50G switchbox to the T-ZACCS 9 TS-960/TS-963.
One switch box can be connected to EI-01P.
Repeater
This repeater can extend the communication distance between devices by an additional 100m!
This repeater is connected between T-ZACCS 9 / T-ZACCS BOX / T-ZACCS UNIT to extend the communication distance.
The distance between devices can be extended by an additional 100m by using this repeater.
Specifications
T-ZACCS 9
Type | TS-963 | |
---|---|---|
Number of measuring point | Using Measurement box | 1000 points at maximum(2000 points at maximum when temperature-integrated strain gauges are used) |
Using both Measurement box and Built-in measurement unit |
||
Using Built-in measurement unit | 30 points (possible up to 60 points when temperature-integrated strain gauges are used) | |
Data update rate Measuring speed |
Display and record measurements update cycle 0.1 sec. | |
High-accuracy mode (0.4 seconds(50Hz)/0.34 seconds(60Hz) | ||
Measurement mode | Initials, Direct, Simple Measure(Temperature measurement is direct only) | |
Simple measure | Factor 1.00, Unit Linked to sensor mode, Decimal point Linked to sensor mode | |
Compensation mode | Comet NON/Comet A/Comet B | |
Monitor | Number of setting table | 5 |
Number of display frame | 0 to 4 | |
Display mode | Value, MAX/MIN, Chart (Y-T), Chart (X-Y), Chart (BAR), Vector | |
Measurement | Manual measurement | Start key (START button on touch screen) |
Automatic measurement | Interval measurement, Comparator measurement, Alarm measurement, Sampling measurement, Sequence measurement | |
Interface | LAN, USB, RS-232C | |
Sensor mode | Strain | Quarter bridge 3-wire 120 / 240 / 350 Ω, Half bridge common dummy |
Half bridge, Full bridge, Full bridge constant current 350Ω | ||
Full bridge high resolution mode, Full bridge 0-2V mode | ||
Full bridge constant current 350Ω high resolution mode | ||
Temperature-integrated strain gauge 120 / 240 / 350 Ω(only when using EI-01P) | ||
Temperature | Thermocouple T, K, J, B, S, R, E, N | |
Pt-RTD Pt100 3W | ||
Voltage | 640mV, 64V | |
Channel setting | Function | Operation with function and operation between channels |
Number of channel | 100 channels | |
Usable variable | Channel, Extended channel, Constant | |
Operation | Four arithmetic operations/General functions/Trigonometric functions/Functions for rosette analysis/Functions for multi-layer inclinometer/Logical functions/Other function |
|
Recording | Internal memory(4Gbyte), SD card(specified by TML) | |
Interface | LAN, USB, RS-232C | |
External dimensions | 328(W)×174(H)×424(D) mm | |
Weight | Approx. 10 kg | |
Power supply | AC100 to 240V 50/60Hz 70VA MAX |
T-ZACCS 9
Type | TS-960 | |
---|---|---|
Number of measuring point | Using Measurement box | 1000 points at maximum (2000 points at maximum when temperature-integrated strain gauges are used) |
Using both Measurement box and Built-in measurement unit | ||
Using Built-in measurement unit | 10 points (up to 20 points when temperature-integrated strain gauges are used) | |
Measuring speed | High-speed mode 0.1 seconds | |
High-accuracy mode 0.4 seconds(50Hz) / 0.34 seconds(60Hz) | ||
Measurement mode | Initial, Direct, Measure (only Direct for temperature measurement) | |
Simple measure | Coefficient: 1.00, Unit: Depends on sensor mode, Decimal point: Depends on sensor mode | |
Compensation mode | Comet NON/Comet A/Comet B | |
Monitor | Number of setting table | 5 |
Number of display frame | 0 to 4 | |
Display mode | Value, MAX/MIN Chart (Y-T), Chart (X-Y), Chart (BAR), Vector | |
Display channel | Value display, MAX/MIN display, Chart display (Y-T), Chart display (X-Y), Chart display (BAR) | |
Measurement | Manual measurement | Start key (START button on touch screen) |
Automatic measurement | Interval measurement, Comparator measurement, Alarm measurement, Sampling measurement, Sequence measurement | |
Interface | LAN, USB, RS-232C | |
Sensor mode | Strain | Quarter bridge 3-wire 120 / 240 / 350 Ω, Half bridge, Half bridge common dummy |
Full bridge, Full bridge high resolution mode, Full bridge constant current350Ω | ||
Full bridge constant current 350Ω high resolution mode, Full bridge 0-2V mode | ||
Temperature-integrated strain gauge 120 / 240 / 350 Ω | ||
Temperature | Thermocouple T/ K/ J/ B/ S/ R/ E/ N | |
Pt-RTD Pt100 3W | ||
Voltage | 640mV, 64V | |
Extended channel setting | Function | Operation with function and operation between channels |
Number of channel | 100 channels | |
Usable variable | Channel, Extended channel, Constant | |
Operation | Four arithmetic operations, General functions, Trigonometric functions, Functions for rosette analysis, Functions for multi-layer inclinometer, Logical functions, Other function | |
Recording | Internal memory (4G byte), SD card (specified by TML) | |
Interface | LAN, USB, RS-232C | |
External dimensions | 328(W)×148(H)×200(D)mm | |
Weight | Approx. 5 kg | |
Power supply | AC100 to 240V 50/60Hz 70VA MAX |
T-ZACCS BOX
Type | EX-50H |
---|---|
Measurement object | Strain gauge, Strain gauge type transducer |
DC voltage, Thermocouple, Pt-RTD | |
Number of measuring point | 50 points |
Measuring speed | High-speed mode 0.1 seconds |
High-accuracy mode 0.4 seconds(50Hz) / 0.34 seconds(60Hz) | |
Number of connection | 20 boxes at maximum |
Extension distance | 100 m (between instruments) |
Connection cable | EX connection cable(CR-89**) |
External dimensions | 320(W)×130(H)×490(D)mm |
Weight | Approx. 10 kg |
Power supply | AC100 to 240V 50/60Hz 104VA MAX |
T-ZACCS UNIT
Type | EU-10H |
---|---|
Measurement object | Strain gauge, Strain gauge type transducer |
DC voltage, Thermocouple, Pt-RTD | |
Number of measuring point | 10 points |
Measuring speed | High-speed mode 0.1 seconds |
High-accuracy mode 0.4 seconds(50Hz) / 0.34 seconds(60Hz) | |
Number of connection | 100 boxes at maximum (including the TS-960 built-in) |
Extension distance | 100 m (between instruments) |
Connection cable | EX connection cable (CR-89**) |
External dimensions | 328(W)×98(H)×183(D)mm |
Weight | Approx. 3 kg |
Power supply | AC100 to 240V 50/60Hz 86VA MAX |
T-ZACCS UNIT
Type | EU-10D | ||
---|---|---|---|
Number of measuring point | 10 points | ||
Supported digital Displacement sensor |
Sensor A(5V) | Sensor B(12V) | |
Compatible connector | R03-PB6M(Manufactured by Tajimi) | R03-PB8M(Manufactured by Tajimi) | |
Sensor supply power | 4.5-5.5V (100mA) | 11.4-12.6V(50mA) | |
Pin assignment | A : Phase A B : Phase B C : +5V D : NC E : GND F : GND |
A : GND B : Phase A C : +12V D : Phase B E : NC F : Shield G : NC H : NC |
|
Input signal | Rectangular wave voltage input | ||
Counting method | Up/down counting by phase difference of phase A + phase B | ||
Measurement range | ±640000 integrated counting | ||
Count reset | When the power is turned ON/FULL count | ||
Number of connected units | UP to 100 units (including TS-960/TS-963 built-in unit) | ||
Extension distance | 100 m (between instruments) | ||
Connection cable | EX connection cable (CR-89**) | ||
External dimensions | 328(W)×98(H)×183(D)mm | ||
Weight | Approx. 3 kg | ||
Power supply | AC100 to 240V 50/60Hz 86VA MAX |
T-ZACCS UNIT
Type | EU-10DO | |
---|---|---|
Function | Trigger/alarm signal output or inter-unit synchronisation signal output | |
Number of output point | 10 points | |
Output | BNC connector | |
Output range | Non-isolated TTL output | DC5V (TTL trigger level) HI (ON) level output voltage: 2.0 V min. LO (OFF) level output voltage: 0.8 V max. |
Non-isolated LVTTL output | DC 3.3V (LVTTL trigger level) DC 3.3V (LVTTL trigger level) |
|
LO (OFF) level output voltage: 0.8 V max. | ||
Max. output current | 3mA MAX | |
Unit synchronisation signal output | Output signal frequency 10Hz | |
Number of connection | 1 unit at maximum | |
Extension distance | 100 m (between instruments) | |
Connection cable | EX connection cable (CR-89**) | |
External dimensions | 328 (W) ×98 (H) ×183 (D) mm | |
Weight | Approx. 3 kg | |
Power supply | AC100 to 240V 50/60Hz 86VA MAX |
T-ZACCS UNIT
Type | EU-10VO |
---|---|
Function | Voltage output of measured value of arbitrary channel |
Number of output point | 10 points |
Output | BNC connector |
Output range | ±10V, ±5V, 0 to +5V |
Calibration output | Zero and arbitrary output in the range of output level |
Number of connection | 2 units at maximum |
Extension distance | 100 m (between instruments) |
Connection cable | EX connection cable(CR-89**) |
External dimensions | 328(W)×98(H)×183(D)mm |
Weight | Approx. 3 kg |
Power supply | AC100 to 240V 50/60Hz 86VA MAX |
T-ZACCS +
Type | EI-01P | |
---|---|---|
Function | Connection with switching box ISW-50G/IHW-50G *Measurement speed and sensor mode depend on switching box |
|
Connection with data logger | ||
Number of connectable units | Up to 20 units (in total including EX-50H) | |
Extension distance | 100m (between devices) | |
Connection cable | Connection cable for EX (CR-89**) | |
Connection with switching box | ||
Target model | IHW-50G, ISW-50G | |
ELECTRICAL (RS-422) | Number of connectable units | 1 unit, 50 points |
Extension distance | 2m | |
Connection cable | Extension cable for ISW/IHW(CR-832M) | |
External dimensions | 160(W)×60(H)×171.5(D)mm | |
Weight | Approx. 1 kg | |
Power supply | AC100 to 240V 50/60Hz 12VA MAX |
T-ZACCS +
Type | EE-00R | |
---|---|---|
Function | Repeater to connect between T-ZACCS 9 and T-ZACCS BOX / T-ZACCS UNIT or between T-ZACCS BOX / T-ZACCS UNIT and T-ZACCS BOX / T-ZACCS UNIT to extend communication distance | |
Connection to data logger | ||
Target model | T-ZACCS9/T-ZACCS BOX/T-ZACCS UNIT | |
Number of connectable units | Up to 99 units connected (10 channels disabled for each additional unit) | |
Up to 99 units connected (10 channels disabled for each additional unit) | 100 m (between instruments) | |
Connection cable | EX connection cable(CR-89**) | |
External dimensions | 160(W)×60(H)×171.5(D)mm | |
Weight | Approx. 1 kg | |
Power supply | AC100 to 240V 50/60Hz 12VA MAX |