A-2 adhesives(Bolt embedding)
Two-component heat-curing epoxy adhesive for bonding BTM strain gauges. Mix the necessary quantity of drugs A and B at the weight ratio of 10 to 1, then pour the mixed adhesive into a hole drilled of the bolt in which the gauge is inserted. Keep at room temperature for 12 hours, then cure at 140°C in furnace for 3 hours.
-
Specifications
TYPE A-2 Two component Heat curing
(Mixing ratio: 10:1)Contents A:25 g *
B:5 g *Component Epoxy Applicable specimen Bolt Operating temperature -30 to +100 ℃ Curing temperature and time Room temperature 12 hrs.
and 140 ℃ 3 hrs.Shelf life 3 months * These contents are for outside Japan.