KLG-A Ground Extension Gauge
NKLG-AB TML-NET type Ground Extension Gauge 200 mm

The KLG-A ground extension gauge is used to measure the displacement of a ground surface. A super-invar wire is set between a stanchion at a reference point (fixed stanchion) and a stanchion at a measurement position (mobile stanchion) and this gauge is mounted on the stanchion at the reference point. The waterproof and environmental resistance features make this gauge suitable for on-site measurement work. The NKLG-AB model is designed specif ically for use with the network
measurement system TML-NET.

Protection ratings : IP 65 equivalent

 

KLG-A Ground Extension Gauge / NKLG-AB TML-NET type Ground Extension Gauge
Features
  • Remote measurement
  • Excellent stability
  • Easy to handle
  • Specifications

    Type Capacity Rated output Non-linearity Temperature range
    KLG-200A 200 mm Approx. 2.5 mV/V
     (5000 x 10-6 strain)
    1 %RO -20 to +60 ℃
     (no incing)
    TML-NET(network measurement system)
    Type Capacity Rated indication Non-linearity Temperature range
    NKLG-200AB 200 mm Approx. 5000 digit 1 %RO -20 to +60 ℃
     (no incing)

    OUTPUT POLARITY

    img-trout-09-1

    Super-invar wire is extended on measurement, ouput turns plus polarity.