KLG-B Ground Extension Gauge
NKLG-BB TML-NET type Ground Extension Gauge 100 mm
The KLG-B ground extension gauge is placed near the ground surface to measure the displacement of a ground slide. A superInvar wire is set between a stanchion at a reference point (fixed stanchion) and a stanchion at a measurement position (mobile stanchion) and this gauge is mounted on the stanchion at the reference point. The waterproof and environmental resistance features make this gauge suitable for on-site measurement work. The NKLG-BB model is designed specifically for use with the network measurement system TML-NET.
Protection ratings : IP 55 equivalent
- Features
- Remote measurement
- Excellent stability
- Easy to handle
-
Specifications
Type Capacity Rated output Non-linearity Temperature range KLG-100B 100 mm Approx. 2.5 mV/V
(5000 x 10-6 strain)1 %RO -20 to +60 ℃
(no incing)TML-NET(network measurement system) Type Capacity Rated indication Non-linearity Temperature range NKLG-100BB 100 mm Approx. 5000 digit 1 %RO -20 to +60 ℃
(no incing)
More Information