Insertion-type inclinometer management software IMP-7210
IMP-7210 is the software for data processing of the measurement data of insertion inclinometers.
The software imports via RS-232C the insertion inclinometer measurement data measured using a measuring instrument (TC-32K/TC-31K) and stored in the data memory, and uses the data to determine the sectional and cumulative displacement of the insertion inclinometer at each depth and outputs graphs such as contrast and distribution diagrams and lists of data.
The measured data of the insertion inclinometer can also be input manually and directly.
- Features
- Observation hole numbers (hereafter referred to as hole numbers) can be set up to 99.
- Compatible with the incremental, normal and multi-channel modes of the measuring instrument (TC-32K/TC-31K).
- Measurement data stored on the memory card of the measuring instrument (TC-32K/TC-31K/TC-31M) can be read directly by a PC for data processing.
- Initial value data can be arbitrarily selected from the measurement data.
- Data from daily rainfall and water level gauges can be input, and can be contrasted and graphed with the measured data of the insertion-type inclinometer.
- The contrast chart, change over time chart, distribution chart and numerical table can be printed.
-
Screen sample
Contrast diagram / Change over time diagram / Distribution diagram
Contrast diagram
Draw a time series of the changes in the distribution of the cumulative displacements of the inclinometer.
Groundwater levels and rainfall figures are drawn at the same time.Change over time diagram
Draws a time series of the change in section displacement at the specified depth of the inclinometer.
Distribution diagram
Draw a distribution chart of sectional or cumulative displacements.
-
Connectable measuring instruments
・TC-32K/TC-31K: Single point measurement (normal mode)
・TC-32K (TC-31K) + CSW-5B: 2-point measurement (multi-channel mode)
(Measurement data stored on the TC-32K's memory card can be read directly by a PC for data processing.)・Inclinometer adapter IA-33
-
System Configuration
OS/PC/Interface/Protected key
OS Microsoft Windows 7(SP1)/8.1/10 PC The above OS environment is recommended, plus a dual-core or higher CPU and CD drive.
HDD capacity: approx. 12 Mbytes or more of free space required for installation.
Free space required for 1 measurement (10 CH x 240 kw) Approx. 5 Mbytes or moreInterface RS-232C Protection key USB dongle