Bolt strain gauge series BTM/BTMC
These gauges are used for measurement of tensile strain of bolt. They are simply inserted into pre-drilled hole in the bolt with exclusive adhesives. This method is recommendable when an ordinary strain gauges can not be mounted on the bolt surface. Accurate tensile force measurement is possible by calibrating the bolt after installing the bolt gauges.
Applicable specimen | Bolt M10 or larger |
---|---|
Operational temperature | -10 to +80℃ |
Temperature compensation range | - |
Applicable adhesive | A-2 |
Backing | Special plastics |
Element | Cu-Ni |
Strain limit | - |
Fatigue life at room temperature | - |
-
Single-element
Gauge lead: polyurethane wire ø0.14, 80 mm
* The cover on the polyurethane wire can be peeled away with a soldering iron, allowing it to be worked later.Type Gauge length (mm) Gauge width (mm) Backing length (mm) Backing width (mm) Resistance (Ω) BTM-1C
(Φ1.6mm)1 0.7 5.6 1.4 120 BTM-6C
(Φ2mm)6 1.0 12.0 1.7 BTM-6CTA
Temperature-integrated(-10 to +80℃)
(Φ2mm)6 1.0 12.0 1.7 Each package contains 10 gauges.
-
We can embed a BTM (bolt strain gauge) into any bolt.
The way of adhering a BTM (bolt strain gauge) differs from a general strain gauge, requiring drilling of the bolt, embedding the strain gauge, and load calibration.
Ex.) Load calibration specifics (bolt size: M10 × 1.25, L = 65)
Load
(kN)0.0 4.6 9.2 13.8 18.4 23.0 Nonlinearity
(%RO)Calibration coefficient
(kN/1×10-6)Indicated strain
(×10-6)0 378 747 1129 1518 1916 1.1 0.0120 [We also embed temperature-integrated BTM (bolt gauge). Contact us for details.]
-
series BTMC
Single-element (G.F. 2.1 approx.)
Type Gauge
length
(mm)Gauge
center
a (mm)Backing
diameter
b (mm)Resistance
(Ω)Applicable
hole diameter
(mm)BTMC-05-D10-003LE 0.5 5 Φ0.9 120 Φ1.0 BTMC-1-D16-003LE 1 5 Φ1.5 120 Φ1.6 BTMC-3-D20-003LE 3 10 Φ1.9 120 Φ2.0 Each package contains 10 gauges.