Strain Gauge Adhesives EB-2 adhesives(Long-term measurement)
EB-2 adhesives(Long-term measurement)
Two-component room-temperature-curing epoxy adhesive for bonding strain gauges for use in temperatures from -60°C to +150°C. Enables stable measurement for a long period of time. Mix the necessary quantity of drugs A and B at the weight ratio of 10 to 3.

-
Specifications
TYPE EB-2 Two component Room-temperature-curing
(Mixing ratio: 10:3)Contents A:10 g x 3
B:3 g x 3Component Epoxy Applicable specimen Metal, Composite Operating temperature -60 to +200 ℃ Curing temperature and time Room temperature 1 day
Pressure 50 to 200kPaShelf life 3 months
More Information
Transducers FAQ
Transducers FAQ
Strain Gauge Adhesives EA-2A adhesives(Cryogenic temperature)
EA-2A adhesives(Cryogenic temperature)
Two-component room-temperature-curing epoxy adhesive for bonding CF series strain gauges for use in temperature from cryogenic ( - 269 ℃) up to 50 ℃. Mix the necessary quantity of drugs A and B at the weight ratio of 2 to 1.

-
Specifications
TYPE EA-2A Two component Room-temperature or heat curing
(Mixing ratio: 2:1)Contents A:25 g *
B:15 g *Component Epoxy Applicable specimen Metal, Concrete, Composite Operating temperature -269 to +50 ℃ Curing temperature and time Pressure at 50 to 300kPa,
Room temperature 1 day or at 50 ℃ 2 hrs.Shelf life 3 months * These contents are for outside Japan.
More Information
Strain Gauge Adhesives C-1 adhesives(Long-term measurement, Transducer-specific)
C-1 adhesives(Long-term measurement, Transducer-specific)
Single-component heat-curing type adhesive. For use on strain gauges that are suited to heat curing. Enables reliable measurement for long periods and in high temperature up to 200°C.

-
Specifications
TYPE C-1 Single component Heat-curing Contents Single 25 g * Component Phenol Applicable specimen Metal Operating temperature -269 to +200 ℃ Curing temperature and time Pre-curing at 130 ℃, 1hr. pressure 200 to 300kPa.
Post-curing at 200 ℃ 1hr. without pressure.Shelf life 3 months * These contents are for outside Japan.
More Information
Strain Gauge Adhesives NP-50B adhesives(High temperature)
NP-50B adhesives(High temperature)
Two-component room-temperature-curing polyester adhesive for bonding QF, ZF and BF series strain gauges. Put the necessary quantity of drug A into the supplied mixing vessel then add drug B by drops to total 3~4% by weight of drug A. Use the mixed adhesive within 5~20 minutes.

-
Specifications
TYPE NP-50B Two component Room-temperature-curing
(Mixing ratio: 2 to 3%)Contents A:25 g *
B:3 g *Component Polyester Applicable specimen Metal, Composite Operating temperature -30 to +300 ℃ Curing temperature and time Room temperature
Pressure 50 to 300kPa
16 hrs.Shelf life 6 months * These contents are for outside Japan.
More Information
Strain Gauge Adhesives PS adhesives(Concrete,Mortar,Wood)
PS adhesives(Concrete,Mortar,Wood)
Two-component room-temperature-curing polyester adhesive. Used as a surface precoating agent for bonding P and PF series gauges to concrete and also as an adhesive for WFLM series gauges. The special filler contained exhibits alkali resistance and effectively shuts off moisture and gas from inside of the concrete. Its high viscosity enables use on vertical walls or ceilings. Put the necessary quantity of drug A in the supplied mixing vessel, then add drug B by drops to total 2~4% by weight of drug A.

-
Specifications
TYPE PS Two component Room-temperature-curing
(Mixing ratio: 2 to 4%)Contents A:25 g *
B:3 g *Component Polyester Applicable specimen Concrete, Mortar, Wood Operating temperature -30 to +100℃ Curing temperature and time Room temperature
2 to 3 hrs.Shelf life 3 months * These contents are for outside Japan.
More Information
Strain Gauge Adhesives RP-2 adhesives(Concrete, Mortar)
RP-2 adhesives(Concrete, Mortar)
Two-component room-temperature-curing polyester adhesive for bonding PF and P series strain gauges. The mixing procedure is the same as above for P-2 adhesive. Put the necessary quantity of drug A in the supplied mixing vessel, then add drug B by drops to total 2~4% by weight of drug A. Use the mixed adhesive within 10~20 minutes.

-
Specifications
TYPE RP-2 Two component Room-temperature-curing
(Mixing ratio: 2 to 4%)Contents A:25 g *
B:3 g *Component Polyester Applicable specimen Concrete, Mortar Operating temperature -30 to +180 ℃ Curing temperature and time Room temperature
Pressure 50 to 300kPa
2 to 3 hrs.Shelf life 3 months * These contents are for outside Japan.
More Information
Strain Gauge Adhesives P-2 adhesives(General purpose)
P-2 adhesives(General purpose)
Two-component room-temperature-curing polyester adhesive for bonding PF, P and F series strain gauges. Put the necessary quantity of drug A in the supplied mixing vessel, then add drug B by drops to total 2~6% by weight of drug A. Use the mixed adhesive within 5~15 minutes.

-
Specifications
TYPE P-2 Two component Room-temperature-curing
(Mixing ratio: 1 to 3%)Contents A:25 g *
B:3 g *Component Polyester Applicable specimen Metal Operating temperature -30 to +180 ℃ Curing temperature and time Room temperature
Pressure 50 to 300kPa
2 to 3 hrs.Shelf life 6 months * These contents are for outside Japan.
More Information