ARE-A-T High capacity Tri-axial Acceleration Transducer 1000 to 5000m/s2
This compact and high-capacity acceleration transducer combines each of the 3 component directions in its casing, allowing simultaneous measurement of acceleration in 3 directions.
Protection ratings : IP 61 equivalent
- Features
- Simultaneous measurement in 3 directions
- Less mutual interference
- Easy to install
-
Specifications
| Type |
Capacity |
Rated output |
Non-linearity |
Temperature range |
| ARE-1000A-T |
1000 m/s2 |
Approx. 0.5 mV/V
(1000x10-6 strain) |
1 %RO |
-10 to +50 ℃ |
| ARE-2000A-T |
2000 m/s2 |
| ARE-5000A-T |
5000 m/s2 |
-10 to +60 ℃ |
Output polarity
Measurement moves in the plus direction when acceleration occurs in the acceleration transducer itself toward the “+” mark on the casing.
High capacity Acceleration Transducer ARE-A
ARE-A High capacity Acceleration Transducer 1000 to 10000m/s2
The ARE-A acceleration transducer is used to measure the acceleration of structures subject to relatively strong vibration. It is small, lightweight and easy to operate.
Protection ratings : IP 61 equivalent
-
Specifications
| Type |
Capacity |
Rated output |
Non-linearity |
Temperature range |
| ARE-1000A |
1000 m/s2 |
Approx. 0.5 mV/V
(1000x10-6 strain) |
1 %RO |
-10 to +50 ℃ |
| ARE-2000A |
2000 m/s2 |
| ARE-5000A |
5000 m/s2 |
-10 to +60 ℃ |
| ARE-10000A |
10000 m/s2 |
Output polarity
Measurement moves in the plus direction when acceleration occurs in the acceleration transducer itself toward the “+” mark on the casing.
High capacity Acceleration Transducer
Flat Compression Load Cell CLH-NA
CLH-NA Compression Load Cell 1MN to 2MN
The CLH-NA is designed mainly to test a cylindrical test specimen made of high-strength concrete.The cylindrical specimen can be directly set on the top of load cell. Also, by using the load cell together with a compressometer, it is possible to measure load and strain simultaneously.
Protection ratings : IP 65 equivalent
- Features
- Guide marking for right placement of specimens with different sizes.
- Easy handling
-
Specifications
| Type |
Applicable
specimen |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
| CLH-1MNA |
Φ10×20 cm |
1MN |
1.5 mV/V
(3000×10-6 strain) ±0.5% |
0.2 %RO |
-20 to +70 ℃ |
| CLH-1.5MNA |
Φ12.5×25 cm |
1.5MN |
| CLH-2MNA |
Φ15×30 cm |
2MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
Flat Compression Load Cell CLL-NA
CLL-NA Compression Load Cell
500kN to 1MN 
The CLL-NA load cells with a flat loading platform are used to conduct loading tests on cylindrical concrete specimens. A cylindrical concrete specimen can be directly set on the surface of the loading platform. By using this load cell together with the compressometer, it is possible to measure load and strain simultaneously.
Protection ratings : IP 65 equivalent
- Features
- Guide marking for right placement of specimens with different sizes
- Easy handling
-
Specifications
| Type |
Applicable
specimen |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
| CLL-500KNA |
Φ10×20 cm |
500kN |
1.5mV/V
(3000×10-6 strain) ±0.5 % |
0.2 %RO |
-20 to +70 ℃ |
| CLL-1MNA |
Φ15×30 cm |
1MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
High-precision Compression Load Cell
High-precision Compression Load Cell CLJ-NB
CLJ-NB Compression Load Cell 50kN to 10MN
CLJ-NBThe CLJ-NB Load Cell is designed considering JIS B 7728 "Load calibration devices for verifying material testing machine" and is the most suitable for verification of single axis compression testing machine. Calibration in accordance with JIS B 7728 is available at extra cost.
Protection ratings : IP 67 equivalent
- Features
- High Precision (0.05 %RO Non-linearity)
- Compatible with remote sensing
-
Specifications
| Type |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
| CLJ-50KNB |
50kN |
2 mV/V
(4000×10-6 strain) or more |
0.05 %RO |
-20 to +70 ℃ |
| CLJ-100KNB |
100kN |
| CLJ-200KNB |
200kN |
| CLJ-300KNB |
300kN |
| CLJ-500KNB |
500kN |
| CLJ-1MNB |
1MN |
| CLJ-2MNB |
2MN |
| CLJ-3MNB |
3MN |
| CLJ-5MNB |
5MN |
| CLJ-10MNB |
10MN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
High-precision Compression Load Cell CLJ-NA
CLJ-NA Compression Load Cell 5kN to 30kN
CLJ-NAThe CLJ-NA Load Cell is designed considering JIS B 7728 "Load calibration devices for verifying material testing machine" and is the most suitable for verification of single axis compression testing machine. Calibration in accordance with JIS B 7728 is available at extra cost.
Protection ratings : IP 65 equivalent
- Features
- High Precision
- Compatible with remote sensing
-
Specifications
| Type |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
| CLJ-5KNA |
5kN |
2 mV/V
(4000×10-6 strain) or more |
0.05 %RO |
-30 to +80 ℃ |
| CLJ-10KNA |
10kN |
| CLJ-20KNA |
20kN |
| CLJ-30KNA |
30kN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
High-precision Compression Load Cell CLM-NB
CLM-NB Compression Load Cell 10kN to 500kN
CLM-NBThe CLM-NB Load Cell is an inert-gas encased load cell in a hermetically sealed package. It offers high precision, high output characteristics and excellent consistency because it uses a shear beam for the strain sensing element. This model is widely used in applications like test equipment.
Protection ratings : IP 65 equivalent
- Features
- High precision, High output
- Optimum for load detection of testing machines
-
Specifications
| Type |
Capacity |
Rated output |
Non-linearity |
Temperature
range |
| CLM-10KNB |
10kN |
2.5 mV/V
(5000×10-6 strain) ±0.2 % |
0.03 %RO |
-30 to +80 ℃ |
| CLM-20KNB |
20kN |
| CLM-50KNB |
50kN |
| CLM-100KNB |
100kN |
| CLM-200KNB |
200kN |
| CLM-500KNB |
500kN |
Output polarity
Measurement moves in the minus direction with regard to increased compressing force.
Low Capacity Acceleration Transducer ARF-A
ARF-A Low capacity Acceleration Transducer 10 to 500m/s2 
The ARF-A acceleration transducer is used to measure the acceleration of structures subject to vibration such as machines, vehicles, ships, civil engineering structures, buildings, and so forth. It is small and lightweight and can make measurement from DC level.
Protection ratings : IP 61 equivalent
- Features
- Measurement from DC level
- Compact
- Easy to install
-
Specifications
| Type |
Capacity |
Rated output |
Non-linearity |
Temperature range |
| ARF-10A |
10 m/s2 |
Approx. 0.5 mV/V (1000x10-6 strain) |
1 %RO |
-10 to +50 ℃ |
| ARF-20A |
20 m/s2 |
| ARF-50A |
50 m/s2 |
| ARF-100A |
100 m/s2 |
| ARF-200A |
200 m/s2 |
| ARF-500A |
500 m/s2 |
Output polarity
Measurement moves in the plus direction when acceleration occurs in the acceleration transducer itself toward the “+” mark on the casing.