Dynamic Strainmeters Analog type Carrier type Dynamic Strainmeter DA-38A

Carrier type Dynamic Strainmeter DA-38A

The DA-38A is a carrier wave type dynamic strainmeter with high frequency response of 10 kHz. It features easy operation and excellent noise resistivity. Digital sensitivity setting method is adopted to enable easy and accurate setting. Also provided is digital display function of measurement value for reliable dynamic measurement. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system.

Carrier type Dynamic Strainmeter DA-38A
Features
  • Frequency response of DC to10 kHz
  • Carrier wave bridge excitation provides excellent resistivity to noise
  • Always checks disconnection of strain gauges and cable
  • Two output monitors provided; Digital display and level meter
  • Lower power consumption compared to conventional models
  • Automatic tracking capacity balancing
  • Reading and automatic setting of TEDS transducer
  • Dual output
  • Built-in low-pass filter
  • Possible external control for balancing and calibration signal output
  • Specifications

    Type DA-38A
    Measuring object Strain
    Number of channels 1 channel
    Measuring range

    ±50000 x 10-6 strain

    Frequency response DC to 10 kHz
    External dimensions 40(W) x 140(H) x 266(D) mm
    Weight Approx. 750 g
    Power supply AC 90 to 264 V 50 / 60 Hz 8.5 VA MAX. (AC100 V)
    DC 10 to 30 V 0.27 A MAX. (DC12 V)

Dynamic Strainmeters Analog type Carrier type Dynamic Strainmeter DA-18A

Carrier type Dynamic Strainmeter DA-18A

The DA-18A is a carrier wave type dynamic strainmeter featuring easy operation and excellent noise resistivity. Digital sensitivity setting method is adopted to enable easy and accurate setting. Also provided is digital display function of measurement value for reliable dynamic measurement. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system. 

Carrier type Dynamic Strainmeter DA-18A
Features
  • Frequency response of DC to 2.5 kHz
  • Carrier wave bridge excitation provides excellent resistivity to noise
  • Equipped with two output monitors; Digital display and level meter
  • Lower power consumption compared to conventional models
  • Automatic tracking capacity balancing
  • Reading and automatic setting of TEDS transducer
  • Dual output
  • Built-in low-pass filter
  • External control possible for balancing and calibration signal output
  • Specifications

    Type DA-18A
    Measuring object Strain
    Number of channels 1 channel
    Measuring range

    ±50000×10-6 strain

    Frequency response DC to 2.5 kHz
    External dimensions 40(W) x 140(H) x 266(D) mm
    Weight 870 g
    Power supply AC 90 to 110 V or 198 to 242 V 50 / 60 Hz 6 VA MAX. (AC100 V)
    DC 10 to 30 V 0.25 A MAX. (DC12 V)

Dynamic Strainmeters Analog type Carrier type Dynamic Strainmeter DA-37A

Carrier type Dynamic Strainmeter DA-37A

The DA-37A is a carrier wave type dynamic strainmeter with high frequency response of 10 kHz. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system.
By installing the units in the exclusive carrying case for computer control, control from a PC via LAN is possible such as settings of sensitivity and low pass filter, operation of balancing and calibration, and acquisition of setting and monitor values.

Carrier type Dynamic Strainmeter DA-37A
Features
  • High frequency response of DC to 10 kHz
  • Digital monitor of output voltage, with indication of maximum / minimum value and open / over
  • Electronic automatic balancing
  • Isolation between input and output
  • Automatic tracking capacity balancing
  • Dual output
  • Built-in low-pass filter
  • Insulation resistance check function for strain gauge bridge
  • External control possible for balancing and calibration signal output
  • Dual power supply of AC and DC
  • Possible control by PC (when installed in exclusive case)
  • Specifications

    Type DA-37A
    Measuring object Strain
    Number of channels 1 channel
    Measuring range

    ±50000×10-6 strain

    Frequency response DC to 10 kHz
    External dimensions 40(W) x 140(H) x 266(D) mm
    Weight Approx. 750 g
    Power supply AC 90 to 132 V 50 / 60 Hz 9.2 VA MAX. (AC100 V)
    DC 10 to 30 V 0.35 A MAX. (DC12 V)

Compression Load Cell CLG-NB

CLG-NB Compression Load Cell
10kN to 200kNCE

The CLG-NB Load Cell is a high precision load cell in a thin, hermetically sealed package. It is widely used in tight spaces and as a system sensor for industrial machinery.

Protection ratings : IP 67 equivalent

Compression Load Cell CLG-NB
Features
  • Hermetically sealed, High precision, High stability
  • Low profile, Easy to install
  • Most applicable as system sensor for industrial machines
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    CLG-10KNB 10kN 2mV/V
    (4000×10-6 strain) ±0.5 %
    0.2 %RO -20 to +70 ℃
    CLG-20KNB 20kN
    CLG-50KNB 50kN
    CLG-100KNB 100kN
    CLG-200KNB 200kN

    Output polarity

    Measurement moves in the minus direction with regard to increased compressing force.

Dynamic Strainmeters Analog type Carrier type Dynamic Strainmeter DA-17A

Carrier type Dynamic Strainmeter DA-17A

The DA-17A is a carrier wave type dynamic strainmeter with frequency response of 2.5 kHz. One unit is for one measurement channel, and two or more units can be installed in an exclusive case or rack to make a multi-channel system. 
By installing the units in the exclusive carrying case for computer control, control from a PC via LAN is possible such as setting of sensitivity and low pass filter, operation of balancing and calibration, and acquisition of setting and monitor values.

Carrier type Dynamic Strainmeter DA-17A
Features
  • Frequency response of DC to 2.5 kHz
  • Digital monitor of output voltage, with indication of maximum / minimum value and open / over
  • Electronic automatic balancing
  • Isolation between input and output
  • Automatic tracking capacity balancing
  • Peak hold function privided
  • Dual output
  • Built-in low-pass filter
  • Insulation resistance check function for strain gauge bridge
  • External control possible for balancing and calibration signal output
  • Dual power supply of AC and DC
  • Possible control by PC (when installed in exclusive case)
  • Specifications

    Type DA-17A
    Measuring object Strain
    Number of channels 1 channel
    Measuring range

    ±50000 x 10-6 strain

    Frequency response DC to 2.5 kHz
    External dimensions 40(W) x 140(H) x 266(D) mm
    Weight Approx. 870 g
    Power supply AC 90 to 132 V 50 / 60 Hz 7.5 VA MAX. (AC100 V)
    DC 10 to 30 V 0.25 A MAX. (DC12 V)

Compression Load Cell CLU-NA

CLU-NA Compression Load Cell
10kN to 1MNCE

The CLU-NA Load Cell is an inert-gas encased load cell in a hermetically sealed package. The strain sensing element has a simple structure that enables highly precise and consistent measurements over long periods of time.

Two independent output type is aslo available on request.

Protection ratings : IP 65 equivalent

Compression Load Cell CLU-NA
Features
  • Long-term stable measurement
  • Easy handling
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    CLU-10KNA 10kN 2mV/V
    (4000×10-6 strain) ±0.2 %
    0.15 %RO -30 to +80 ℃
    CLU-20KNA 20kN
    CLU-50KNA 50kN
    CLU-100KNA 100kN
    CLU-200KNA 200kN
    CLU-500KNA 500kN
    CLU-1MNA 1MN

    Output polarity

    Measurement moves in the minus direction with regard to increased compressing force.

Compression Load Cell CLP-NB

CLP-NB Compression Load Cell
 10kN to 10MN CE

CLP-NBThe CLP-NB is a general purpose compression load cell having a column shape strain sensing element. A variety of capacities ranging from 10 kN to 10 MN is available.

Dual output type having two independent inputs and outputs is also available on request.

Protection ratings : IP 65 equivalent

圧縮型荷重計 CLP-NB
Features
  • Load cell having appropriate capacity can be chosen among various types
  • Easy to handle
  • CE marking compliant
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    CLP-10KNB 10kN 1.5mV/V
    (3000×10-6 strain) ±0.2 %
    0.1% RO -20 to +70 ℃
    CLP-20KNB 20kN
    CLP-30KNB 30kN
    CLP-50KNB 50kN
    CLP-100KNB 100kN
    CLP-200KNB 200kN
    CLP-300KNB 300kN
    CLP-500KNB 500kN
    CLP-1MNB 1MN
    CLP-2MNB 2MN
    CLP-3MNB 3MN
    CLP-5MNB 5MN 0.2% RO
    CLP-10MNB 10MN

    Output polarity

    Measurement moves in the minus direction with regard to increased compressing force.