Cavity type Pressure Transducers PWH-PA

PWH-PA High capacity Pressure Transducer 70 to 200MPaCE

The PWH-PA high-capacity pressure transducer has a sealed structure made with high-strength stainless steel.Owing to this structure, stable high-accuracy measurement can be made over a long period of time. It is used to control plant or production lines, to measure jack pressure, and for various other applications.

Protection ratings : IP 65 equivalent

PWH-PA High capacity Pressure Transducer
Features
  • Excellent stability, High precision
  • Easy handling
  • Specifications

    Type Capacity Rated output Non-linearity Temperature range
    PWH-70MPA 70MPa 1 mV/V (2000x10-6  strain)±1 % 0.2 %RO -20 to +70 ℃
    PWH-100MPA 100MPa
    PWH-150MPA 150MPa
    PWH-200MPA 200MPa

    Output polarity

    Measurement moves in the plus direction with regard to an increase in pressure.

Cavity type Pressure Transducers PW-PAH

PW-PAH High temperature Pressure Transducer 2 to 50MPa

The PW-PAH pressure transducer is designed to measure pressure of fluids like oil and water or gases like air in high temperature. Since it is constructed small, it can be used in a narrow space. These models line up five ranges of 2, 5, 10, 20 and 50MPa.

Protection ratings : IP 65 equivalent

PW-PAH High temperature Pressure Transducer
Features
  • Usable at high temperatures
  • Small and lightweight
  • Easy handling
  • Specifications

    Type Capacity Rated output Non-linearity Temperature range
    PW-2MPAH 2MPa 2 mV/V (4000x10-6  strain)±25 % 0.3 %RO -40 to +170 ℃
    PW-5MPAH 5MPa
    PW-10MPAH 10MPa
    PW-20MPAH 20MPa
    PW-50MPAH 50MPa

    Output polarity

    Measurement moves in the plus direction with regard to an increase in pressure.

Extensometer EDP-A/EDP-B

EDP-A/EDP-B Extensometer 5mmCE

The EDP series Displacement Transducers are designed to measure elongation in round metal rod or sheet metal test specimen. It has a special holder that simply and securely holds the transducer in place, and the elongation in the test specimen is detected based on displacement between two knife edges. This series uses strain gauges for the sensing element and can be connected to an ordinary strainmeter for high precision measurements.

Protection ratings : IP 20 equivalent

EDP-A/EDP-B Extensometer
Features
  • Compact, Easy handling
  • Secure fixing to specimen
  • Extremely small spring force
  • High sensitivity, High precision
  • Specifications

    Type Capacity Gauge Length Rated output Sensitivity
    (x10-6 strain/mm)
    Non-linearity Temperature range
    EDP-5A-50 5 mm 50 mm Approx. 3mV/V
    (6000x10-6
    strain)
    Approx. 1200 0.3%RO 0 to +40℃
    (no icing)
    EDP-5B-50

General Use Strain Gauge F series GOBLET

F series GOBLET general use strain gaugegoblet_log_s CE_logo

These are CE marked strain gauges originated from general use strain gauge F series. They are compliant with RoHS 2 Directive 2011/65/EU and supplied with CE marking. These strain gauges are available as GOBLET besides the conventional F series gauges which are the most commonly used strain gauges in our product line. The backing of this strain gauge is color coded for identification of the material for self-temperature-compensation. Extension leadwires are also available with CE marking.

General Use Strain Gauge F series GOBLET
Applicable specimen Metal, Ceramics, Composite
Operational temperature -196 to +150 ℃
Temperature compensation range +10 to +100 ℃
Applicable adhesive CN, P-2, EB-2
Backing Special plastics
Element Cu-Ni alloy foil
Strain limit 5 % (50000 x 10-6 strain)
Fatigue life at room temperature 1 x 106 (±1500 x 10-6 strain)
  • For general measurement  Single-element / two-element / three-element

    Single-element (G.F. 2.1 approx.)

    Gauge pattern Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    length
    (mm)

    Backing
    width
    (mm)

    Resistance (Ω)
    flgb_111 FLGB-02-11
    FLGB-02-17
    FLGB-02-23
    0.2 1.4 3.5 2.5 120
    FLGB-1-11
    FLGB-1-17
    FLGB-1-23
    1 1.1 6 2.5 120
    flab_311 FLAB-03-11
    FLAB-03-17
    FLAB-03-23
    0.3 1.4 3 2 120
    FLAB-05-11
    FLAB-05-17
    FLAB-05-23
    0.5 1.2 4.3 2.2 120
    FLAB-1-11
    FLAB-1-17
    FLAB-1-23
    1 1.3 5 2.5 120
    FLAB-1-350-11
    FLAB-1-350-17
    FLAB-1-350-23
    1 1.6 4.5 3 350
    FLAB-1W-350-11
    FLAB-1W-350-17
    FLAB-1W-350-23
    1 2 4.7 3.6 350
    FLAB-2-11
    FLAB-2-17
    FLAB-2-23
    2 1.5 6.5 3 120
    FLAB-2-350-11
    FLAB-2-350-17
    FLAB-2-350-23
    2 1.9 6 3.5 350
    FLAB-3-11
    FLAB-3-17
    FLAB-3-23
    3 1.7 7.7 3.5 120
    FLAB-3-60-11
    FLAB-3-60-17
    FLAB-3-60-23
    3 1.2 7.7 3 60
    FLAB-3-350-11
    FLAB-3-350-17
    FLAB-3-350-23
    3 1.6 7.2 3 350
    FLAB-3W-350-11
    FLAB-3W-350-17
    FLAB-3W-350-23
    3 3.2 8.5 5 350
    FLAB-5-11
    FLAB-5-17
    FLAB-5-23
    5 1.5 10 3 120
    FLAB-5-350-11
    FLAB-5-350-17
    FLAB-5-350-23
    5 1.8 9.4 3.8 350
    FLAB-6-11
    FLAB-6-17
    FLAB-6-23
    6 2.2 11 4.3 120
    FLAB-6-1000-11
    FLAB-6-1000-17
    FLAB-6-1000-23
    6 4.6 11 7 1000
    FLAB-10-11
    FLAB-10-17
    FLAB-10-23
    10 2.5 15.4 5 120
    FLAB-30-11
    FLAB-30-17
    FLAB-30-23
    30 2 35 5 120
    flkb_611 FLKB-1-11
    FLKB-1-17
    FLKB-1-23
    1 0.7 4.5 1.4 120
    FLKB-2-11
    FLKB-2-17
    FLKB-2-23
    2 0.9 5.5 1.5 120
    FLKB-6-11
    FLKB-6-17
    FLKB-6-23
    6 1 11 2.2 120
    FLKB-10-11
    FLKB-10-17
    FLKB-10-23
    10 1.6 15 3.8 120

    Each package contains 10 strain gauges.

     

    2-element 0°/90° Stacked type (G.F. 2.1 approx.)

    Gauge pattern Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    length
    (mm)

    Backing
    width
    (mm)

    Resistance (Ω)
    fcab_211 FCAB-1-11
    FCAB-1-17
    FCAB-1-23
    1 0.7 Φ4.5 120
    FCAB-1-350-11
    FCAB-1-350-17
    FCAB-1-350-23
    1 1.6 Φ8 350
    FCAB-2-11
    FCAB-2-17
    FCAB-2-23
    2 0.9 Φ7 120
    FCAB-2-350-11
    FCAB-2-350-17
    FCAB-2-350-23
    2 1.9 Φ9.5 350
    FCAB-3-11
    FCAB-3-17
    FCAB-3-23
    3 1.7 Φ11 120
    FCAB-3-350-11
    FCAB-3-350-17
    FCAB-3-350-23
    3 2 Φ10 350
    FCAB-5-11
    FCAB-5-17
    FCAB-5-23
    5 1.9 Φ12 120
    FCAB-5-350-11
    FCAB-5-350-17
    FCAB-5-350-23
    5 1.8 Φ10 350
    FCAB-6-11
    FCAB-6-17
    FCAB-6-23
    6 2.4 Φ14 120
    FCAB-10-11
    FCAB-10-17
    FCAB-10-23
    10 2.5 Φ17 120

    Each package contains 10 strain gauges.

     

    3-element 0°/45°/90° Stacked type (G.F. 2.1 approx.)

    Gauge pattern Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    length
    (mm)

    Backing
    width
    (mm)

    Resistance (Ω)
    frab_211 FRAB-1-11
    FRAB-1-17
    FRAB-1-23
    1 0.7 Φ4.5 120
    FRAB-1-350-11
    FRAB-1-350-17
    FRAB-1-350-23
    1 1.6 Φ8 350
    FRAB-2-11
    FRAB-2-17
    FRAB-2-23
    2 0.9 Φ7 120
    FRAB-2-350-11
    FRAB-2-350-17
    FRAB-2-350-23
    2 1.9 Φ9.5 350
    FRAB-3-11
    FRAB-3-17
    FRAB-3-23
    3 1.7 Φ11 120
    FRAB-3-350-11
    FRAB-3-350-17
    FRAB-3-350-23
    3 2 Φ10 350
    FRAB-5-11
    FRAB-5-17
    FRAB-5-23
    5 1.9 Φ12 120
    FRAB-5-350-11
    FRAB-5-350-17
    FRAB-5-350-23
    5 1.8 Φ10 350
    FRAB-6-11
    FRAB-6-17
    FRAB-6-23
    6 2.4 Φ14 120
    FRAB-10-11
    FRAB-10-17
    FRAB-10-23
    10 2.5 Φ17 120

    Each package contains 10 strain gauges.

  • Glass/Ceramic materials use

    Gauge pattern Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    length
    (mm)

    Backing
    width
    (mm)

    Resistance (Ω)
    Single-element (G.F. 2.1 approx.)
    flab_58
    FLAB-2-8 2 1.5 6.5 3 120
    FLAB-5-8 5 1.5 10 3 120
    90°2-element Rosette (G.F. 2.1 approx.) Stacked type
    fcab_28
    FCAB-2-8 2 0.9 Φ7 120
    FCAB-5-8 5 1.9 Φ12 120
    45°/90° 3-element Rosette (G.F. 2.1 approx.) Stacked type
    frab_58
    FRAB-2-8 2 0.9 Φ7 120
    FRAB-5-8 5 1.9 Φ12 120

    Each package contains 10 strain gauges.

  • Dedicated integral lead wire recommended for F series

    For general use of GOBLET (qualified for CE marking)

    Application Product name Lead wire code Applicable temperature of leadwire (℃) Example of type name
    General use (without temperature change) Paralleled vinyl LJB-F -20 to +80 FLAB-5-11-3LJB-F
    Paralleled vinyl LJC-F FLAB-5-11-3LJC-F
    General use 3-wire paralleled vinyl LJBT-F -20 to +80 FLAB-5-11-3LJBT-F
    3-wire paralleled vinyl LJCT-F FLAB-5-11-3LJCT-F
    Middle - high temperature 3-wire paralleled vinyl LXT-F -20 to +150 FLAB-5-11-3LXT-F
    1-gauge 4-wire Polypropylene 4-wire paralleled (modular plug attached) LQM-F -20 to +100 FLAB-5-11-3LQM-F

    Only the leadwires using lead-free solder are available for GOBLET strain gauges with CE marking.
    Note that “-F” is appended to the type name of the leadwire using lead-free solder.

  • Standard leadwire integrated strain gauge

    Single-element

    Used leadwire: 0.11 mm2 Total resistance of leadwire per meter: 0.32 Ω

    img_flab_ljb

    Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    length
    (mm)

    Backing
    width
    (mm)

    Resistance
    (Ω)
    Lead wire pre-attached Type name of lead wire preattached
    FLAB-1-11
    FLAB-1-17
    FLAB-1-23
    1 1.3 5 2.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F
    FLAB-2-11
    FLAB-2-17
    FLAB-2-23
    2 1.5 6.5 3 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F
    FLAB-3-11
    FLAB-3-17
    FLAB-3-23
    3 1.7 7.7 3.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F
    FLAB-5-11
    FLAB-5-17
    FLAB-5-23
    5 1.5 10 3 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F
    FLAB-6-11
    FLAB-6-17
    FLAB-6-23
    6 2.2 11 4.3 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJC-F
    -3LJC-F
    -5LJC-F
    -3LJCT-F
    -5LJCT-F

    Minimum order quantity is 10 gauges.

     

    2-element 0°/90° rosette

    Used leadwire: 0.08 mm2 Total resistance of leadwire per meter: 0.44 Ω

    img_fcab_ljb

    Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    (mm)
    Resistance
    (Ω)
    Lead wire pre-attached Type nameof lead wire preattached
    FCAB-1-11
    FCAB-1-17
    FCAB-1-23
    1 0.7 Φ4.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FCAB-2-11
    FCAB-2-17
    FCAB-2-23
    2 0.9 Φ7 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FCAB-3-11
    FCAB-3-17
    FCAB-3-23
    3 1.7 Φ11 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FCAB-5-11
    FCAB-5-17
    FCAB-5-23
    5 1.9 Φ12 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FCAB-6-11
    FCAB-6-17
    FCAB-6-23
    6 2.4 Φ14 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FCAB-10-11
    FCAB-10-17
    FCAB-10-23
    10 2.5 Φ17 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F

    Minimum order quantity is 10 gauges.

     

    3-element 0°/45°/90° rosette

    Used leadwire: 0.08 mm2 Total resistance of leadwire per meter: 0.44 Ω

    img_frab_ljb

    Type

    Gauge
    length
    (mm)

    Gauge
    width
    (mm)

    Backing
    (mm)
    Resistance
    (Ω)
    Lead wire pre-attached Type name of lead wire preattached
    FRAB-1-11
    FRAB-1-17
    FRAB-1-23
    1 0.7 Φ4.5 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FRAB-2-11
    FRAB-2-17
    FRAB-2-23
    2 0.9 Φ7 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FRAB-3-11
    FRAB-3-17
    FRAB-3-23
    3 1.7 Φ11 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FRAB-5-11
    FRAB-5-17
    FRAB-5-23
    5 1.9 Φ12 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FRAB-6-11
    FRAB-6-17
    FRAB-6-23
    6 2.4 Φ14 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5 m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F
    FRAB-10-11
    FRAB-10-17
    FRAB-10-23
    10 2.5 Φ17 120 Paralleled 1 m
    Paralleled 3 m
    Paralleled 5m
    3-wire 3 m
    3-wire 5 m
    -1LJB-F
    -3LJB-F
    -5LJB-F
    -3LJBT-F
    -5LJBT-F

    Minimum order quantity is 10 gauges.

Concrete Compression Testing Sensor CLL-NA

CLL-NA Compression Load Cell 500kN to 1MNCE

This is a load cell with a flat loading surface. It is used to conduct strength tests on cylindrical concrete specimens. Guide marks on the loading surface allow cylindrical concrete specimens of different sizes to be easily aligned.

Protection ratings : IP 65 equivalent

CLL-NA Compression Load Cell
Features
  • Convenient guide marks
  • Easy handling
  • Specifications

    Type Applied specimen Capacity Rated output Non-linearity Temperature range
    CLL-500KNA ø10 x 20 cm 500 kN

    1.5 mV/V
     (3000 x 10-6 strain) ±0.5 %

    0.2 %RO -20 to +70 ℃
    CLL-1MNA ø15 x 30 cm 1 MN

Concrete Compression Testing Sensor CM-H

CM-H Compressometer (Destructive) 
20000 x 10-6 strainCE

The CM-10H compressometer is designed to conduct a breaking strength test. It measures the compression strain on a cylindrical concrete specimen (10 cm in diameter x 20 cm in length) made of generally used concrete or high-strength concrete. The high-sensitivity strain gauge is assembled into this compressometer to measure the amount of strain. Both the high-sensitivity strain gauge and a cylindrical concrete specimen are provided with coverings to protect them from damage. A cylindrical concrete specimen can be set in the compressometer quickly and easily. This compressometer allows the strain on a wet concrete specimen, taken out right after underwater curing, to be measured. With this compressometer linked with either the CLL-NA or CLH-MNA load meter, it is also possible to measure the modulus of static elasticity.

CM-H Compressometer (Destructive)
Features
  • Usable till destruction of a specimen
  • Easy to install
  • Possible strain measurement of wet specimen
  • Repeated use
  • Specifications

    Type Applicable specimen Gauge length Capacity
    CM-10H ø10 x 20 cm 100 mm 20000 x 10-6 strain

Concrete Compression Testing Sensor CM

CM Compressometer 
50000 x 10-6 strain to 33000 x 10-6 strainCE

The CM compressometer is designed to conduct a strength test. It measures the axial strain on a cylindrical concrete specimen placed in and secured by screws to the inner chamber of this compressometer. It uses a high-sensitivity strain gauge to measure the amount of strain. By multiplying a measurement by a certain factor, the amount of strain can be calculated as a numerical value. Unlike the case of ordinary strain gauges, this compressometer is simple and easy to operate and can be used repeatedly. However, it cannot be used to conduct breaking tests.

CM Compressometer
Features
  • Easy to install
  • Repeated use
  • Easy drawing of stress- strain curve
  • Specifications

    Type Applicable specimen Gauge length Capacity
    CM-10 ø10 x 20 cm 100 mm 50000 x 10-6 strain
    CM-12 ø12.5 x 25 cm 125 mm 40000 x 10-6 strain
    CM-15 ø15 x 30 cm 150 mm 33000 x 10-6 strain