ワイヤレスデータ収録システム ワイヤレスコントローラ ZT-120

Wireless Data Recording System Wireless Controller ZT-120

The wireless data recording system consists of the wireless module ZT-014 and the wireless controller ZT-120.
The wireless module incorporates an A/D converter that converts measurement data from strain gage transducers into digital data for interval measurement, data recording, and monitoring. Since wiring from the sensor to the controller can be made wireless, it is ideal for measurement in locations where wiring of measurement cables is difficult or detracts from the landscape, or for measurement of moving objects, reducing wiring labor and costs.
Measurement data is stored in the memory of the wireless module, and the wireless controller and PC are brought in periodically to collect the data.

Wireless Data Recording System Wireless Controller ZT-120
Features
  • Communication distance is approximately 50m in line-of-sight
  • Wireless controller is connected to PC via USB and powered by USB bus power
  • Up to 20 wireless modules can be controlled (setting, data collection, monitoring)
  • Specifications

    Type Wireless Controller ZT-120
    Number of wireless
    module connections

    Up to 20 units
    (regardless of simultaneity between each channel)

    Communication system 2.4GHz band IEEE802.15.4 protocol compliant (number of channels: 15)
    External interface USB 2.0 compliant (cable length: approx. 1.7 m)
    Power supply voltage DC4.7V to 5.3V (supplied via USB)
    External dimensions 30(W)× 25(H)× 65(D)mm(excluding projected parts)
    Weight approx. 130g (including antenna)

System block diagram

img-zt120-02

Application examples

Dynamic observation of retaining wall inclination (inclinometer), anchor tension (center-hole load cell), and observation wells (water level gauge); data can be collected wirelessly by visiting the site periodically

img-zt120-zt014-02_0

Suspended load management of cranes
On-line measurement of moving objects with difficult cabling, etc.

img-zt120-zt014-03_2

PC-connected Measuring Instruments

USB Strain Converter DSCUSB

The DSCUSB is an on-line measuring instrument that connects to a PC via a USB interface. A sensor input conversion cable is included, allowing direct connection of strain-gauge transducers.
Compact and power supply-free. Measurements can be made easily and reports can be generated immediately. 
This product is imported from Mantracourt Electronics Limited, UK.

USB Strain Converter DSCUSB
Features
  • Pocket-sized, weighing only 45 grams
  • No power supply required (using USB bus power)
  • Data is recorded in CSV format. Data can be organised using familiar spreadsheet software.
  • Measurement with multiple units possible (using a USB hub).
  • Conversion cable with NDIS connector included
  • Specifications

    Type DSCUSB
    measurement object Strain gauge transducers (4-gauge 80 to 5000 Ω)
    Number of measuring point 1(Can be used with multiple units)
    bridge power supply DC5V
    Measuring range ±3mV/V (±6000×10-6strain)
    A/D conversion 24bit
    Sampling frequency 1, 2, 5, 10, 20, 50, 60, 100, 200 Hz
    Recording interval Can be set arbitrarily between 10ms and 32s
    Filter Recursive filters (IIR) Programmable
    Interface USB
    OS Windows 7/8/8.1/10
    Operating temperature and humidity range -40 to +85℃ 95%RH or less (excluding condensation)
    External dimensions 71(W)×20(H)×51(D) (Excluding connectors)
    Weight 45g(Main unit only)
    Power Supplied from USB bus power

Please download the standard software “DSCUSB Toolkit” from the link below.

Concrete static modulus of elasticity test software DC-7972 for PC control Dynamic Strainmeter DC-004P

Concrete static modulus of elasticity test software DC-7972 for PC control Dynamic Strainmeter DC-004P

This software is used to determine the static modulus of elasticity of concrete by measuring load, strain, etc. using the PC control Dynamic Strainmeter DC -004P.
Sensors used repeatedly, such as load cells and compressometers, can be registered in advance to enable efficient calculation of the concrete static modulus of elasticity and other parameters.
The software complies with JIS A 1149 Test Method for Static Modulus of Elasticity of Concrete.
 

PCコントロール型動ひずみ測定器DC-004P用 コンクリート静弾性係数試験ソフトウェア DC-7972
Features
  • Compressive strength, static modulus of elasticity and Poisson's ratio can be calculated and printed from measured values.
  • TEDS sensor compatible, CSV data storage possible.
  • Selection of pre-registered sensors allows the input of data for each test to be omitted.
  • Dynamic strain measurement ensures that peak values are not missed.
  • System configuration

    OS / PC / Interface / Protection key

    Compatible measuring instruments PC control Dynamic Strainmeter DC-004P

     

    OS Microsoft Windows Vista SP1/7/8/8.1
    PC A CD drive that meets the specifications recommended by the above operating systems
    Interface  USB 2.0 (2 ports)
    Protection key USB dongle

Insertion inclinometer management

Insertion-type inclinometer management software IMP-7210

IMP-7210 is the software for data processing of the measurement data of insertion inclinometers.
The software imports via RS-232C the insertion inclinometer measurement data measured using a measuring instrument (TC-32K/TC-31K) and stored in the data memory, and uses the data to determine the sectional and cumulative displacement of the insertion inclinometer at each depth and outputs graphs such as contrast and distribution diagrams and lists of data.
The measured data of the insertion inclinometer can also be input manually and directly.

Features
  • Observation hole numbers (hereafter referred to as hole numbers) can be set up to 99.
  • Compatible with the incremental, normal and multi-channel modes of the measuring instrument (TC-32K/TC-31K).
  • Measurement data stored on the memory card of the measuring instrument (TC-32K/TC-31K/TC-31M) can be read directly by a PC for data processing.
  • Initial value data can be arbitrarily selected from the measurement data.
  • Data from daily rainfall and water level gauges can be input, and can be contrasted and graphed with the measured data of the insertion-type inclinometer.
  • The contrast chart, change over time chart, distribution chart and numerical table can be printed.
  • Screen sample

    Contrast diagram / Change over time diagram / Distribution diagram

    Contrast diagram

    fig1

    Draw a time series of the changes in the distribution of the cumulative displacements of the inclinometer.
    Groundwater levels and rainfall figures are drawn at the same time.

    Change over time diagram

    fig2

    Draws a time series of the change in section displacement at the specified depth of the inclinometer.

    Distribution diagram

    fig3

    Draw a distribution chart of sectional or cumulative displacements.

  • Connectable measuring instruments

    ・TC-32K/TC-31K: Single point measurement (normal mode)

    ・TC-32K (TC-31K) + CSW-5B: 2-point measurement (multi-channel mode)
     (Measurement data stored on the TC-32K's memory card can be read directly by a PC for data processing.)

    ・Inclinometer adapter IA-33

  • System Configuration

    OS/PC/Interface/Protected key

    OS Microsoft Windows 7(SP1)/8.1/10
    PC The above OS environment is recommended, plus a dual-core or higher CPU and CD drive.
    HDD capacity: approx. 12 Mbytes or more of free space required for installation.
    Free space required for 1 measurement (10 CH x 240 kw) Approx. 5 Mbytes or more
    Interface RS-232C
    Protection key USB dongle

Embedment Type Inclination Transducer

Embedment Type Inclination Transducer KB-P ±5°to ±10°

Used for measuring landslide displacement in the ground and displacement of structures.
It is connected in a multi-stage system to the measurement point together with a dedicated relay pipe in a borehole of ø 66 mm or more.
The inclinometer is fixed by injecting grout into the gap between the borehole and the inclinometer. (Built-in arrestor)

Protection rating: IP68 equivalent

Embedment Type Inclination Transducer KB-P
Features
  • Made of all stainless steel for excellent corrosion resistance
  • Excellent reliability
  • Easy automatic measurement
  • Specifications

    Type Capacity Rated output Non-linearity Temperature range
    KB-5P ±5°

    Approx. 1mV/V(2000x10-6 strain)

    1%RO -20 to +60℃
    KB-10P ±10°

    Output polarity

    The measured value moves in the direction of the arrow on the label on the body of the unit in relation to the change in inclination.