Socket Wrench Torque Transducer

LTA-NA Torque Transducer 50N・m to 500N・m

The LTA-NA Torque Transducer is a high precision transducer that is used to measure tightening force on nuts and bolts. Compact and light weight, it is mounted between the socket and the socket wrench handle. Although the transducer uses a strainmeter to take readings, it can be used to take peak readings simply by connecting it to a peak hold measuring instrument.

Protection ratings : IP 40 equivalent

LTA-NA Torque Transducer
Features
  • Small, Lightweight
  • Easy handling
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    LTA-50NA 50N・m

    2mV/V

    (4000x10-6 strain) ±2%

    0.3%RO -10 to +60 ℃
    LTA-100NA 100N・m
    LTA-200NA 200N・m

    3mV/V

    (6000x10-6 strain) ±2%

    LTA-500NA 500N・m

    2mV/V

    (4000x10-6 strain) ±2%

Load Cell Accessories

LOAD CELL ACCESSORIESCE

FA SPHERICAL CAP

FA

The FA Spherical Cap is mounted to the top of a compression load cell for accurate transmission of compression loads.

exampleA exampleB
s_load1 s_load2

FB-M MOUNTING FLANGE

FB-M

The FB-M Mounting Flange is used to mount Rod Ends and Eye Bolts to TCLM-NB type load cells.

exampleC
s_load3

FB MOUNTING FLANGE

FB

The FB Mounting Flange is used when the mounting area for a compression load cell is unstable or when load cells can not be secured from the bottom.

exampleD
s_load4

FC SLIDE SUPPORT

FC

The FC Slide Support can be used to eliminate lateral loads from compression load cells for high precision measurements.

exampleD
s_load4

FD ROTARY ATTACHMENT

FD

The FD Rotary Attachment ensures smooth load transmission by eliminating torsion during tension load measurements.

exampleE
s_load5

FE ROD END

FE

The FE Rod End is ideal when a tension/compression universal load cell is used to measure tension loads on machinery and structures.

exampleC exampleE
s_load3 s_load5

FF EYE BOLT

FF

The FF Eye Bolt is used when tension/compression universal load cells are used to measure tension. It can be used with FH Shackle.

exampleF
s_load6

FG LOAD BUTTON

FG

The FG Load Button is used when tension/compression universal load cells are used to measure compression.

exampleB
s_load2

FH SHACKLE

FH

The FH Shackle is used with tension load cells in instances such as measuring wire tension.

exampleF
s_load6

Monitoring System Controller

Network Measurement System
Monitoring System Controller MD-111

The monitoring system makes flexible use of TML-NET measurement system. The system consists of controller, network modules and TML-NET compatible transducers. The controller MD-111 controls the network modules and the transducers at specified intervals and stores measurement data in SD card. It is suitable for installation in an instrument storage box or cabinet, and is equipped with input/output contacts. Accordingly, it is most suited for making a measurement system of small scale.

Network Measurement System / Monitoring System Controller MD-111
Features
  • Automatic measurement by sleep interval function
  • Driven by DC power source
  • Small, light and available for installation on DIN rail
  • Number of measurement point can be extended easily
  • Measurement data are stored in SD card
  • Alarm via contact output
  • Specifications

    Type MD-111
    Maximum number of connection Low-comsumption module 100 modules
    Conventional module 20 modules(Connection distance up to 150 m)
    Maximum extension distance Low-comsumption module 1km or less
    Conventional module 1km or less (for 10 modules or less)
    Connecting cable Exclusive 2-core shielded cable 2-1.25L1
    Number of measurement point 100 points
    Function Interval measurement, Monitoring
    Measurement mode Simple measure mode
    Function of TML-NETset-up Channnel number setting of network module
    (Available when connecting only one module)
    Interval timer 1, 2, 5, 10, 15, 20, 30 minutes, 1, 2, 3, 4, 6, 12, 24 hours
    (The starting time of measurement can be specified)
    Memory card SD memory card (TML specified)
    Contact input One point: Non-voltage contact, Open collector signal
    Contact output One point: Relative value, Upper/lower limit value
    Dimensions 95(W) x 30(H) x 100(D)mm
    Weight Approx. 200g
    Power supply DC4.2 to 6.8V
    DC9 to 18V

System Block Diagram

img-md111-02_e

 

Cantilever type Displacement Transducer

CE Cantilever type Displacement Transducer 2mm to 10mmCE

The CE displacement transducer has the structure of strain gauges mounted on a cantilever. The high responsiveness to displacement and the simple structure allow this transducer to make accurate and stable measurement and to be installed in a confined space.

CE Cantilever type Displacement Transducer
Features
  • High Response
  • Excellent Stability
  • Easy handling
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6strain/mm)
    Non-linearity Temperature range
    CE-2 2mm Approx. 2.5mV/V
    (5000x10-6strain)
    Approx. 2500 1%RO 0 to +40℃
    CE-5 5mm Approx. 1000
    CE-10 10mm Approx. 500

    Output polarity

    img-trout-04

    Measurement moves in the minus direction when the contact tip is pushed inward.

Low Capacity 3-component Load Cell

Low capacity 3-component load cell SLP-NA-T 100N to 1kN

The SLP-NA-T is a strain gauge based load cell for simultaneous measurement of forces in three mutually perpendicular axes.  Since the load cell is constructed small and light, it is well suited to use in model testing.
 
Protection ratings : IP 65 equivalent

Low capacity 3-component load cell SLP-NA-T
Features
  • Small and light
  • Good response
  • Easy handling
  • Applicable to wind tunnel testing and vibration testing of models
  • Specifications

    Type Capacity Rated output Non-linearity Temperature
    range
    SLP-100NA-T 100N 0.5mV/V
    (Approx. 2000×10-6 strain)
    0.5%RO  -20 to +80 ℃
     (no icing)
    SLP-200NA-T 200N
    SLP-500NA-T 500N
    SLP-1KNA-T 1kN

Transducer Related Product

Transducer Related Product

Cable Connector Cap BC-9 / BC-9A

ケーブル用コネクタキャップ BC-9/BC-9A

To protect the connectors from dust and water droplets, such as advanced cable converter.

Type Notes
BC-9 ø9mm Cable only
BC-9A-1 ø9mm 0.5mm2 4-core shielded chloroprene cable 1m NDIS Plug or long with loose end

Cable Cap

ケーブル用キャップ

Tip to protect it from dust and water droplets, such as cable converter.
The following eight types of the diameter of the cable.

Cable Cap ø2.4mm
ø3mm
ø4.6mm
ø6mm
ø7mm
ø9mm
ø11.5mm
ø16.5mm

Joint Kit

ジョイントキット

When coating is to extend the cable kit.
We gathered the materials I need to protect cable connections will facilitate joint work.

Instrumentation Cable

計測用ケーブル

Used to extend the Civil Engineering Transducer cable.

Type Names Coating diameter 1m length
CT6-4V100 ø6mm 0.3mm2
4-core shielded vinyl cable
6mm 100m
CT6-4N100 ø6mm 0.35mm2
4-core shielded chloroprene cable
6mm 100m
CT9-4N100 ø9mm 0.5mm2
4-core shielded chloroprene cable
9mm 100m
CT11.5-4N100 ø11.5mm 0.5mm2
4-core shielded chloroprene cable
11.5mm 100m
CT9-5N100 ø9mm 0.3mm2
5-core shielded chloroprene cable
9mm 100m
CT11.5-5N100 ø11.5mm 0.5mm2
5-core shielded chloroprene cable
11.5mm 100m

Transducers cable

4-core shielded chloroprene cable ø9mm 0.5mm2
Type Length type
CT9-4N0.5/NJ-STB 0.5m NDIS Jack to Long with loose end
CT9-4N10/NP-STB 10m NDIS Plug to Long with loose end
CT9-4N2/WP-NP 2m Waterproof plug to NDIS Plug
CT9-4N5/WP-NP 5m Waterproof plug to NDIS Plug
CT9-4N10/WP-NP 10m Waterproof plug to NDIS Plug
CT9-4N20/WP-NP 20m Waterproof plug to NDIS Plug
CT9-4N30/WP-NP 30m Waterproof plug to NDIS Plug
CT9-4N2/WP-STB 2m Waterproof plug to Long with loose end
CT9-4N5/WP-STB 5m Waterproof plug to Long with loose end
CT9-4N10/WP-STB 10m Waterproof plug to Long with loose end
CT9-4N20/WP-STB 20m Waterproof plug to Long with loose end
CT9-4N30/WP-STB 30m Waterproof plug to Long with loose end