Strain gauge coding system

Strain gauge coding system

Strain gauges are coded as follows. Click the details button under each segment to view details.

img-codingsys-01

Color coding for test specimen

Most of strain gauges are self-temperature-compensated. Strain gauges in Series F, UF, CF and WF are color coded in three types according to the material for compensation.

Test specimen Coefficient of thermal expansion Backing color Gauge type exampled
Mild steel 11×10-6/℃

output polarity

Red

FLA-5-11
Stainless steel
Copper alloy
17×10-6/℃

output polarity

Brown

FLA-5-17
Aluminum 23×10-6/℃

output polarity

Green

FLA-5-23

 

Basic coding of type “details”

Gauge series

output polarity

F General purposeF series of GOBLET are CE marked. GF Low elastic use
CCFXX Stress concentration measurement BF/UBF/DSF Composite material use, CE marked.
WF Waterproof construction, CE marked. CF Cryogenic temperature use, CE marked.
PF Concrete use, Polyester foil gauge, CE marked. CEF Wide range temperature use, CE marked.
P Concrete use, Polyester wire gauge, CE marked. QF/ZF/EF High temperature use, CE marked.
FLM/WFLM Concrete use, Metal backing strain gauge SFA Stress measurement, CE marked.
MF Magnetic field use AW Weldable strain gauge, CE marked.
PMF Concrete use, Embedment type strain gauge BTM Bolt axial strain measurement, CE marked.
YEF/YF/YHF Post-yield strain (Large strain) measurement, CE marked. DD One-side gauge
PMFLS Asphalt use, Embedment type strain gauge FAC Crack detection gauge, CE marked.
LF Wood and gypsum use TF Strain gauge type temperature measurement
PFLW/PLW Low elastic material use, Wood, Gypsum FGMH Frictional Strain Checker

 Pattern configuration

output polarity

L/LA/LK/LX/LG/BX/BY Single
LAB/LKB/LGBoutput polarity
C/CA/LC/CS/CB 2-axis Cross
CABoutput polarity
R/LR/RA/RAS/RS 3-element Rosette 
RABoutput polarity
XV/YV/BXV/BYV 5-element Single
CV 5-element 2-axis Cross
CT Torque
LT 45° Single

* Not indicated for some types
Cross: 2-axis 0°/90° gauge
Rosette: 3-axis 0°/45°/90° gauge

 Function and applied strain gauge

output polarity

  Functions Applicable gauge
A Left 45° QFLT
B Right 45° QFLT
T Thermocouple type, temperature-integrated Compatible with almost all foil strain gauges
W Wide Some FLAB, QFLAB 350 Ω

* This is not coded for general strain gauges without the above functions.   

Material for temperature compensation  ×10-6/℃

output polarity

3 Composite material 17 Stainless steel/Copper alloy
Ceramic (Si3N4) 2.6 to 3.3 SUS304 16.2
CFRP 3 to 5 SUS310 15.8
5 Composite material SUS316 16.0
Ceramic (SiC) 4.6 SUS321 16.7
CFRP 3 to 5 Copper 16.7
8 Composite material/glass Beryllium copper 16.6
Soda glass 7.9 Brass 16.7
Titanium 8.9 Bronze 17.0
Titanium alloy (Ti-6Al-4V) 8.8 Constantan 14.9
11 Mild steel 23 Aluminium
Mild steel (0.1-0.2C) 11.8 Aluminium 23.4
Hard steel(0.4-0.5C) 11.2 Aluminium 2024-T4 23.0
Cast iron 10.5 Lead and its alloy 29.0
Hastelloy-276 11.2 Gypsum 25.0
Inconel 600 13.3 Polyimide 20 to 30
Inconel 750 12.1 28 Magnesium
Monel 13.5 Magnesium alloy 27.0
SUS 630 (17-4PH) 10.8 50 Plastics
SUS 631 (17-7PH) 10.6 Epoxy (Cast) 45 to 65
Concrete 7 to 13 70 Plastics
    Acrylics 70
    ABS 74
    Polyacetal (POM) 80
    Polycarbonate (PC) 66 to 70
    Polystyrene (PS) 60 to 80

* Strain gauges not having a coefficient of thermal expansion for temperature compensated materials are not self-temperature compensated.

Option (-F) 

output polarity

Option code "-F" is added after the type name of the strain gauge to designate that lead-free solder is used for the strain gauge.  For strain gauges that are qualified for CE marking (such as FLAB, PL, PFL series, etc.), "-F" is not added.

Length of lead wire in meter

output polarity

2-wire system Standard length 1, 3, 5
3-wire system Standard length 3, 5

* Other lengths are available on request. 

Suffix code of pre-attached lead wire

output polarity

LJB / LJB-F 2-wire parallel vinyl wire 7/0.12 (0.08mm2)
LJBT / LJBT-F 3-wire parallel vinyl wire (3-wire system)
LJC / LJC-F 2-wire parallel vinyl wire 10/0.12 (0.11mm2)
LJCT / LJCT-F 3-wire parallel vinyl wire (3-wire system)
LJD 2-wire parallel vinyl wire 12/0.18 (0.3mm2)
LJDT 3-wire parallel vinyl wire (3-wire system)
LH 2-strand twisted vinyl wire 5/0.07 (0.02mm2)
LHT 3-strand twisted vinyl wire (3-wire system)
LS ø3.2-mm 2-conductor shielded vinyl wire 7/0.12 (0.08mm2)
LTSA / LTSA-F ø3-mm 3-conductor shielded vinyl wire
LTSB / LTSB-F ø5-mm 3-conductor shielded vinyl wire 7/0.26 (0.3mm2)
LQM / LQM-F Polypropylene 4-wire parallel wire 7/0.12 (0.08mm2)
LXT / LXT-F 3-wire parallel special vinyl wire
LJRA 2-strand twisted cross-linked vinyl wire 7/0.16 (0.14mm2)
LJRTA 3-strand twisted cross-linked vinyl wire 7/0.127 (0.09mm2)
LJQTA / LJQTA-F 3-strand twisted cross-linked polyethylene wire
TLJBT / TLJBT-F Temperature-integrated 3-wire parallel vinyl wire 7/0.12 (0.08mm2)
6FB♦TLT / 6FB♦TLT-F Temperature-integrated 3-strand twisted FEP single-core wire 1/0.2
LP / LP-F Polyurethane wire 1/0.14、1/0.18
LU / LU-F Polyester wire
LE / LE-F Polyimide wire
6FA♦LT/6FA♦LT-F 3-strand twisted FEP wire 7/0.18 (0.18mm2)
6FAS♦LT/6FAS♦LT-F 3-strand twisted FEP wire  Easy adhesion
6FB♦LT/6FB♦LT-F 3-strand twisted FEP single-core wire 1/0.2
6FC♦LT/6FC♦LT-F 3-strand twisted FEP wire 7/0.08 (0.04mm2)
6FD♦LTS ø1.5-mm 3-conductor shielded FEP wire
4FA♦LT/4FA♦LT-F 3-strand twisted PTFE wire 7/0.16 (0.14mm2)
4FB♦LT/4FB♦LT-F 3-strand twisted PTFE single-core wire 1/0.2

* For further information on leadwires such as electrical resistance, dimensions, etc.

Option (-F)

output polarity

Option code "-F" is added after the type name of the leadwire to designate that lead-free solder is used for the leadwire.