General Displacement Transducer

SDP-E Displacement Transducer 50 to 300mmCE

This is a strain gauge type displacement transducer for general purpose. This transducer has a small cantilever inside, and displacement is mechanically converted into deflection of the cantilever. Strain, which is proportional to the deflection, is generated on the cantilever and is measured by strain gauges.
Stable measurement is possible even for a small displacement. The scale and pointer on the main body enables easy positioning of the transducer.
For SDP-200E and SDP-300E, a dual-output type with two independent input/output ports is optionally available. 

Protection ratings : IP 40 equivalent

 

SDP-E Displacement Transducer
Features
  • Excellent Stability
  • Easy handling
  • Convenient visual scale
  • Specifications

    Type Capacity Rated output

    Sensitivity
    (x10-6 strain/mm)

    Non-
    linearity
    Temperature
    range
    SDP-50E 50 mm

    2.5 mV/V
    (5000×10-6 strain)
    ±0.2 %

    100 0.2 %RO -10 to +60 ℃
    SDP-100E 100 mm 50
    SDP-200E 200 mm 5mV/V
    (10000×10-6 strain)
    ±0.3 %
    50 0.3 %RO
    SDP-300E 300 mm approx. 33

    Output polarity

    Measurement moves in the minus direction when the shaft is pushed inward.

SDP-ET Displacement Transducer 50/100mmCE

The SDP-ET displacement transducer is a general-purpose, strain gauge type transducer, and features measurement of tension displacement using hook bolt. Designed with a strain-generating cantilever, it is able to make stable measurement while maintaining the high sensitivity to minuscule displacements.(When measuring displacement via a wire, be sure to take into account loss of sensitivity due to elongation of the wire.)

 

Protection ratings : IP 40 equivalent

 

DP-ET Displacement Transducer
Features
  • Excellent Stability
  • Convenient visual scale
  • Tensile displacement measurement available
  • Specifications

    Type Capacity Rated output

    Sensitivity
    (×10-6 strain/mm)

    Non-
    linearity
    Temperature
    range
    SDP-50ET 50 mm

    2.5 mV/V
    (5000x10-6 strain) ±0.2 %

    100 0.2 %RO -10 to +60 ℃
    SDP-100ET 100 mm 50

    Output polarity

    Measurement moves in the minus direction when the shaft is pushed inward.