Low Elastic Strain Gauge Wood, Gypsum Use
LF series Strain gauges for Wood and Gypsum
LF series strain gauges for wood and gypsum are foil gauges utilizing special plastic for the backing. The grid pattern is suited for measurement on materials having a low elastic modulus and reduces the stiffening effect of the strain gauge on the specimen. Gauges are self-temperature-compensated for 11×10-6/℃ materials.
A new series of strain gauges bearing the CE mark, GOBLET, has been added. This CE-compliant series of products is compliant with RoHS directives. These gauges exceed the capabilities of conventional strain gauges with lead-free soldering as well as a unique tab design. CE-compliant extension lead wires are also available.
Applicable specimen | Wood, Gypsum |
---|---|
Operational temperature | LF :-30 to +80 ℃ LF:-20 to +80 ℃ |
Temperature compensation range | +10 to +80 ℃ |
Applicable adhesive | CN-E |
Backing | Special plastics |
Element | Cu-Ni |
Strain limit | 3% (30000 x 10-6 strain) |
Fatigue life at room temperature | 1 x 106 (±1500 x 10-6 strain) |
-
LOW ELASTIC MATERIALS - WOOD, GYPSUM USE
Gauge pattern Type Gauge
length
(mm)Gauge
width
(mm)Backing
length
(mm)Backing
width
(mm)Resistance
(Ω)LFLAB-10-11 10 3.1 18.5 5.3 120 Each package contains 10 gauges.
* Attachment of lead wiring can be performed (made-to-order). -
LOW ELASTIC MATERIALS - WOOD, GYPSUM USE
Gauge pattern Type Gauge
length
(mm)Gauge
width
(mm)Backing
length
(mm)Backing
width
(mm)Resistance
(Ω)LFLA-10-11 10 3.1 18.5 5.3 120 Each package contains 10 gauges.
* Attachment of lead wiring can be performed (made-to-order). -
Lead wires recommended for LF series strain gauges (made-to-order)
Lead wires recommended for LF series strain gauges
Purpose Lead wires Lead wire symbol Operating temperature range
(℃ )Gauge type exampled General measurement
(no temperature change)2-wire parallel vinyl wire LJC/LJC-F -20 to +80 LFLA-10-11-3LJC General measurement 3-wire parallel vinyl wire LJCT/LJCT-F -20 to +80 LFLA-10-11-3LJCT * Only lead wires using lead-free solder are available for GOBLET series strain gauges with the CE marking.
More Information
PFLW/PLW series WOOD-long term use strain gauge
This gauge has a thin metal backing for long term measurement on woods, not affected by moisture contained in wood. The gauge is bonded with PS adhesive.
Applicable specimen | Wood |
---|---|
Operational temperature | -20 to +80 ℃ |
Temperature compensation range | +10 to +80 ℃ |
Applicable adhesive | PS |
Backing | Polyester |
Element | Cu-Ni (wire) |
Strain limit | 2% (20000 x 10-6 strain) |
Fatigue life at room temperature | 1 x 105 (±1000 x 10-6 strain) |
-
Single-element(G.F. 2.1 approx.)
Type Gauge
length
(mm)Gauge
width
(mm)Backing
length
(mm)Backing
width
(mm)Resistance
(Ω)PFLW-30-11 30 2.3 40 7 120 PFLW-30-11 60 1 74 8 120 * Optional -F availability (lead-free solder)
Each package contains 10 gauges. -
Lead wires recommended for PFLW/PLW series strain gauges (made-to-order)
Purpose Lead wires Lead wire symbol Operational temperature range
(℃)Gauge type exampled General measurement
(no temperature change)2-wire parallel vinyl wire LJC-F -20 to +80 PFLW-30-11-3LJC-F General measurement 3-wire parallel vinyl wire LJCT-F -20 to +80 PFLW-30-11-3LJCT-F Medium/high temperature 3-wire parallel special vinyl wire LXT-F -20 to +150 PFLW-30-11-3LXT-F 1-gauge 4-wire method Polypropylene 4-wire parallel wire
(with modular)LQM-F -20 to +100 PFLW-30-11-3LQM-F -
Leadwire-integral PFLW/PLW series (single-element)
0.11 mm2 integral vinyl leadwire Total leadwire resistance per meter : 0.32 Ω
Type Gauge
length
(mm)Gauge
width
(mm)Backing
length
(mm)Backing
width
(mm)Resistance
(Ω)Lead wire
pre-attachedType name
of lead wire
preattachedPFLW-30-11 30 2.3 40 7 120 Paralleled 1m
Paralleled 3m
Paralleled 5m
3-wire 3m
3-wire 5m-1LJC-F
-3LJC-F
-5LJC-F
-3LJCT-F
-5LJCT-FPFLW-30-11 60 1 74 8 120 Paralleled 1m
Paralleled 3m
Paralleled 5m
3-wire 3m
3-wire 5m-1LJC-F
-3LJC-F
-5LJC-F
-3LJCT-F
-5LJCT-F* Optional -F availability (lead-free solder)
Each package contains 10 gauges.
More Information