Dynamic Measurement Software
Dynamic Strain Recorder Measurement Software DC-7630
This is measurement software for multichannel dynamic measurement using a compact strain recorder DC-204R, DC-204Ra / DC-104R, or DC-104Ra. Combined use with a recorder DC-204/104 series is possible, with up to 8 units, 32 channels controllable simultaneously. Graph is displayable in real time, allowing measurement while checking a dynamic waveform. Unified management of measurement conditions/settings and data allow settings and measurement data to be viewed on the same screen. Supports CSV format and DADiSP compatible formats for text file conversion of data.
- Features
- DC-204/104 series simultaneous control sampling and data recording
- Up to 8 units, 32 points of sampling and data recording
- Real-time graph display during sampling
- Automatic measurement setting: data trigger measurement, interval measurement, data compilator measurement
- Up to 100 computed points
- Settings for carrying out measurement and measurement results can be managed all together for a measurement project. Can be interfaced onscreen for viewing.
-
System configuration
OS / computer / interface / product key
OS Microsoft Windows 7(SP1)/8.1/10/11 Computer Any meeting specifications recommended by above OSes, CD drive
Memory: 500 MB or more
HDD space: 1 GB or more available spaceInterface USB Product key USB dongle
Option
DC-7630-M (Synchronous retrieval of motion images and data)
Measurement and storage of motion images with DirectX compatible camera are made together, and the recorded measurement data and images can be synchronously retrieved.
DC-7630 System Requirements
OS | Microsoft Windows 7(SP1)/8/8.1/10 |
---|---|
Computer | Any meeting specifications recommended by above OSes, CD drive Memory: 2 GB or more HDD space: 100 GB or more available space recommended on the hard disk to which data is being saved 4 GB or more available space recommended on the OS hard disk |
Interface | USB |
Product key | USB dongle |
Supported cameras or USB video capture
For camera OS supporting DirectShow or DirectX, DV video camera recognized as streaming media, USB-connected web camera, display-integrated camera, industrial cameras compatible with IEEE1394
To use IEEE1394, the computer required a IEEE1394 terminal or interface board
Video camera connected to USB video capture
Dynamic Multi-Recorder Measurement TMR-7630
This is measurement software for multichannel dynamic measurement and data processing using the multirecorder TMR-200/300 series. Up to 10 units of any input device can be selected and connected for up to 80 channels of simultaneous control.
Waveforms can be displayed in real time while sampling, allowing measurement while viewing dynamic waveforms. Unified management of measurement conditions/settings and data allow settings and measurement data to be viewed on the same activated screen. Supports CSV format and DADiSP compatible formats for text file conversion of data. Created graphs can be saved to BMPEMP and PNG formats, allowing not only creation of reports, but also import to and editing with commercially available software. Support for TMR-211 option frequency processing library (TMR-211-01), for real-time frequency processing.
- Features
- Real-time graph display during sampling
- Unified management of measurement conditions/settings and data
- Up to 1000 expansion channels by measurement data possible
- Data from other measurement data file can be overlaid on graph
- Multitude of graph formats possible, by adding waveforms, values, X-Y monitor graphs, history graphs, spectrographs, and frequency graphs
- Automatic measurement clearing and continuation when CF card becomes full
- Automatic data recording possible with measurement from interval, data trigger, external trigger, free run, data compilator, program, etc.
- Data trigger measurement, free run measurement, or program measurement can be used offline
- Select and retrieve data from CF card installed on computer
- Supports CSV format and DADiSP compatible formats for text file conversion of data.
-
TMR-7630/TMR-7630-H system configuration
OS / computer / interface / product key
OS Microsoft Windows 7(SP1)/8.1/10/11 Computer Any meeting specifications recommended by above OSes, CD drive
Memory: 4 GB or more
HDD space: 10 GB or more available space recommended on the hard disk to which data is being saved
4 GB or more available space recommended on the OS hard diskInterface LAN:100BASE-TX or better
USB:USB2.0Product key USB dongle
Option
TMR-7630H (Frequency analysis)
The frequency process and S-N analysis of expanded channels for later frequency analysis of the measured dynamic waveform are possible.
TMR-7630-M (Synchronous retrieval of motion images and data)
Measurement and storage of motion images with DirectX compatible camera are made together, and the recorded measurement data and images can be synchronously retrieved.
TMR-7630-M System Requirements
OS | Microsoft Windows 7(SP1)/8/8.1/10 |
---|---|
Computer | Core Duo or better multiprocessor recommended, CD drive Memory: 4 GB or more HDD space: 10 GB or more available space recommended on the hard disk to which data is being saved 4 GB or more available space recommended on the OS hard disk |
Interface | LAN:100BASE-TX or better USB:USB2.0 |
Product key | USB dongle |
Supported cameras or USB video capture
For camera OS supporting DirectShow or DirectX, DV video camera recognized as streaming media, USB-connected web camera, display-integrated camera, industrial cameras compatible with IEEE1394
To use IEEE1394, the computer required a IEEE1394 terminal or interface board
Video camera connected to USB video capture
Dynamic Measurement Software RD-7640
Real-time data recording software Visual LOG RD-7640 can control our measuring instruments DS-50A, TMR-311, TFM-104, and display and record measurement data in real time. This measurement software controls each measuring instrument, and can carry out monitor, manual, data trigger, and interval measurement of 1 to 1000 measurement channels and up to 1000 expansion channels. Waveforms from recorded data files can be viewed with any software that can import DADiSP-format files, however, our software for displaying waveforms, Visual LOG WF-7630, is required for viewing data from expanded channels.
- Features
- Always processes data on par with the sampling speed of the instrument, improving monitor and alarm accuracy.
- Real-time FFT analysis
- Long-time continuous recording
- Simultaneous recording of 3 types of measurement (manual, data trigger, interval)
- Arithmetic computation/rosette analysis possible between channels
-
System configuration
OS / computer / interface / product key / applicable measuring instruments
OS Microsoft Windows 7(SP1)/8.1/10/11 Computer Intel Core i5 3.0 GHz or faster CPU recommended (excl. Turbo Boost)
Conforms to OS system requirements
Memory: 4 GB or more
HDD space: 5 GB or more available space * Alert appears when available space is less than 5 GB.Interface LAN Product key USB dongle Applicable measuring instruments Multichannel digital dynamic strainmeter DS-50A up to 1000 channels (20 units at same time)
Multirecorder TMR-311 up to 320 channels (4 units × 10 units connected)