Hydraulic jack control unit

Hydraulic jack control unit

This device is used for load/displacement control and holding control of hydraulic jacks, and can control 2 or 4 systems. The amplifier can be controlled by a personal computer for auto-zero, range setting, calibration, etc. The detected load and displacement can be calculated by the PC as a sum of two points, averaged, etc., to control the load and displacement of the jack as desired.

Product Configuration

  • Sensor

  • Control unit

  • Electric pump unit

Features
  • 2 or 4 hydraulic jack systems can be controlled
  • Amplifier can be mounted up to 12 channels
  • PC control of auto-zero, range setting, calibration, etc. possible
  • Detected load and displacement can be calculated by summing two points, averaging, etc.
  • Load and displacement control of jacks can be automatic or manual
  • Electric pump and control solenoid valve integrated
  • Manual push/pull control is possible
  • Specification

    Sensor Force transducer, displacement transducer
    Amplifier unit Number of
    measurement points
    2 or 4 points (up to 12 points possible)
    Applicable
    Transducers
    350Ω strain gage applied transducers
    A/D converter Resolution 12 bits
    PC Please contact us
    Displays Please contact us
    Actuator Number of jack
    control points
    2 or 4 points
    Emergency stop possible
    Manual pressurization/
    decompression control
    possible
    Control software Initial settings Amplifier sensitivity setting, rated capacity, used capacity, rated output
    Control Mode  Target display of load and displacement, holding control
    Others Numerical display, status display, graph control, arithmetic processing
    Operating temperature and humidity range 0 to +40°C, 95% RH or less (excluding condensation)
    Power source Rated voltage AC100V 50/60Hz
    Allowable voltage AC90 to 110V 50/60Hz
    External dimensions 700 (W) x 1346 (H) x 700 (D) mm (excluding projections)
    Weight Approx. 100 kg
    Operation relay unit  Control system 2 or 4 systems
    Control method Isolated photocoupler
    Solenoid valve ON/OFF by time control
    Control solenoid valve Control system 2 or 4 systems
    Hydraulic pressure 49MPa(500kgf/cm2
    Flow rate control Aperture valve, push/pull 2 systems
    Power source AC180 to 220V 50/60Hz
    Electric pump Discharge pressure,
    flow rate
    49MPa (500kgf/cm2) 0.3L/min
    4.9MPa (50kgf/cm2) 5.6L/min
    Cooler Water-cooled (optional)
    Effective oil storage capacity approx. 45 L
    External dimensions 1000 (W) x 1400 (H) x 950 (D) mm (excluding projections)
    Weight Approx. 650kg

System block diagram

””