Hydraulic jack control unit
Hydraulic jack control unit
This device is used for load/displacement control and holding control of hydraulic jacks, and can control 2 or 4 systems. The amplifier can be controlled by a personal computer for auto-zero, range setting, calibration, etc. The detected load and displacement can be calculated by the PC as a sum of two points, averaged, etc., to control the load and displacement of the jack as desired.
Product Configuration
-
Sensor
-
Control unit
-
Electric pump unit
- Features
- 2 or 4 hydraulic jack systems can be controlled
- Amplifier can be mounted up to 12 channels
- PC control of auto-zero, range setting, calibration, etc. possible
- Detected load and displacement can be calculated by summing two points, averaging, etc.
- Load and displacement control of jacks can be automatic or manual
- Electric pump and control solenoid valve integrated
- Manual push/pull control is possible
-
Specification
Sensor Force transducer, displacement transducer Amplifier unit Number of
measurement points2 or 4 points (up to 12 points possible) Applicable
Transducers350Ω strain gage applied transducers A/D converter Resolution 12 bits PC Please contact us Displays Please contact us Actuator Number of jack
control points2 or 4 points Emergency stop possible Manual pressurization/
decompression controlpossible Control software Initial settings Amplifier sensitivity setting, rated capacity, used capacity, rated output Control Mode Target display of load and displacement, holding control Others Numerical display, status display, graph control, arithmetic processing Operating temperature and humidity range 0 to +40°C, 95% RH or less (excluding condensation) Power source Rated voltage AC100V 50/60Hz Allowable voltage AC90 to 110V 50/60Hz External dimensions 700 (W) x 1346 (H) x 700 (D) mm (excluding projections) Weight Approx. 100 kg Operation relay unit Control system 2 or 4 systems Control method Isolated photocoupler
Solenoid valve ON/OFF by time controlControl solenoid valve Control system 2 or 4 systems Hydraulic pressure 49MPa(500kgf/cm2) Flow rate control Aperture valve, push/pull 2 systems Power source AC180 to 220V 50/60Hz Electric pump Discharge pressure,
flow rate49MPa (500kgf/cm2) 0.3L/min
4.9MPa (50kgf/cm2) 5.6L/minCooler Water-cooled (optional) Effective oil storage capacity approx. 45 L External dimensions 1000 (W) x 1400 (H) x 950 (D) mm (excluding projections) Weight Approx. 650kg
System block diagram