High Sensitive Displacement Transducer

CDP-M Small Displacement Transducer 5 to 100mm

The CDP-M is a small and high sensitive displacement transducer. Compared with conventional CDP series, its output is the same but its diameter is less by 50 - 20% than that of CDP, and its temperature range is extended up to +80°C. The CDP-M with cable output along the measurement axis and the CDP-MT with cable output vertical to the axis are available. The transducer can be used not only for static measurement but also for quasi-dynamic measurement. A fixing holder is supplied as a standard accessory. Options include ordinary magnet stand MB-B and small MB-PSL specified for the CDP-M series.

Protection rantings : IP 40 equivalent

CDP-M Small Displacement Transducer
Features
  • Compact
  • Easy handling
  • Allowable temperature range -10 to +80℃
  • Lineup of five models: 5 / 10 / 25 / 50 / 100 mm
  • High output of 10000 x 10-6 strain or more
  • CDP-5M/-10M Only CE Marking Compliant
  • Specifications

    Type Capacity Rated output Sensitivity
    (×10-6 strain/mm)
    Non-
    linearity
    Temperature
    range
    CDP-5M
    CDP-5MT
    5 mm 5 mV/V
    (10000x10-6 strain) ±0.3 %
    2000 0.3 %RO -10 to +80 ℃
     (no condensation)
    CDP-10M
    CDP-10MT
    10 mm 1000
    CDP-25M
    CDP-25MT
    25 mm 6.25 mV/V
    (12500x10-6 strain) ±0.3 %
    500
    CDP-50M
    CDP-50MT
    50 mm 5 mV/V
    (10000x10-6 strain) ±0.3 %
    200
    CDP-100M
    CDP-100MT
    100 mm 100

    Output polarity

    img-trout-01

    Measurement moves in the minus direction when the shaft is pushed inward.

CDP Displacement Transducer 5 to 100mmCE

The CDP is a compact and easy-to-operate displacement transducer. Because it is designed to produce a large output and to deliver stable performance, highly accurate measurements can be made. It is suitable for both static and dynamic measurements.

Protection ratings : IP 40 equivalent

高感度変位計 CDP
Features
  • High precision, High output
  • Excellent Response
  • Easy handling
  • Specifications

    Type Capacity Rated output Sensitivity
    (x10-6 strain/mm)
    Non-
    linearity
    Temperature
    range
    CDP-5 5 mm 5 mV/V
    (10000x10-6 strain) ±0.1 %
    2000 0.15 %RO -10 to +60 ℃
     (no condensation)
    CDP-10 10 mm 5 mV/V
    (10000x10-6 strain) ±0.1 %
    1000 0.1%RO
    CDP-25 25 mm 6.25mV/V
    (12500x10-6 strain) ±0.1 %
    500
    CDP-50 50 mm 5mV/V
    (10000x10-6 strain) ±0.1 %
    200
    CDP-100 100 mm 100

    Output polarity

    img-trout-01-1

    Measurement moves in the minus direction when the shaft is pushed inward.

CDP-D Displacement Transducer with dual ports 50 to 100mm

The CDP-D displacement transducer is the CDP displacement transducer with dual isolated I/O ports. For example, one set of input and output cables can be connected to an analog measuring instrument and the other set to a digital measuring instrument. With two different types of measuring equipment connected to this transducer, simultaneous measurements can be made without interference.

Protection ratings : IP 40 equivalent

CDP-D Displacement Transducer with dual ports
Features
  • Measurement with two readout units
  • High precision, High output
  • Excellent response
  • Easy handling
  • Specifications

    Type Capacity Rated output Sensitivity
    (×10-6 strain/mm)
    Non-
    linearity
    Temperature
    range
    CDP-50-D 50 mm 5 mV/V
    (10000×10-6 strain)
    ±0.1 %
    200 0.1 %RO -10 to +60 ℃
    (no condensation)
    CDP-100-D 100 mm 100

    Output polarity

    img-trout-01_0

    Measurement moves in the minus direction when the shaft is pushed inward.