High Sensitive Displacement Transducer
CDP-M Small Displacement Transducer 5 to 100mm
The CDP-M is a small and high sensitive displacement transducer. Compared with conventional CDP series, its output is the same but its diameter is less by 50 - 20% than that of CDP, and its temperature range is extended up to +80°C. The CDP-M with cable output along the measurement axis and the CDP-MT with cable output vertical to the axis are available. The transducer can be used not only for static measurement but also for quasi-dynamic measurement. A fixing holder is supplied as a standard accessory. Options include ordinary magnet stand MB-B and small MB-PSL specified for the CDP-M series.
Protection rantings : IP 40 equivalent
- Features
- Compact
- Easy handling
- Allowable temperature range -10 to +80℃
- Lineup of five models: 5 / 10 / 25 / 50 / 100 mm
- High output of 10000 x 10-6 strain or more
- CDP-5M/-10M Only CE Marking Compliant
-
Specifications
Type Capacity Rated output Sensitivity
(×10-6 strain/mm)Non-
linearityTemperature
rangeCDP-5M
CDP-5MT5 mm 5 mV/V
(10000x10-6 strain) ±0.3 %2000 0.3 %RO -10 to +80 ℃
(no condensation)CDP-10M
CDP-10MT10 mm 1000 CDP-25M
CDP-25MT25 mm 6.25 mV/V
(12500x10-6 strain) ±0.3 %500 CDP-50M
CDP-50MT50 mm 5 mV/V
(10000x10-6 strain) ±0.3 %200 CDP-100M
CDP-100MT100 mm 100 Output polarity
Measurement moves in the minus direction when the shaft is pushed inward.
More Information
CDP Displacement Transducer 5 to 100mm
The CDP is a compact and easy-to-operate displacement transducer. Because it is designed to produce a large output and to deliver stable performance, highly accurate measurements can be made. It is suitable for both static and dynamic measurements.
Protection ratings : IP 40 equivalent
- Features
- High precision, High output
- Excellent Response
- Easy handling
-
Specifications
Type Capacity Rated output Sensitivity
(x10-6 strain/mm)Non-
linearityTemperature
rangeCDP-5 5 mm 5 mV/V
(10000x10-6 strain) ±0.1 %2000 0.15 %RO -10 to +60 ℃
(no condensation)CDP-10 10 mm 5 mV/V
(10000x10-6 strain) ±0.1 %1000 0.1%RO CDP-25 25 mm 6.25mV/V
(12500x10-6 strain) ±0.1 %500 CDP-50 50 mm 5mV/V
(10000x10-6 strain) ±0.1 %200 CDP-100 100 mm 100 Output polarity
Measurement moves in the minus direction when the shaft is pushed inward.
More Information
CDP-B Splashproof High Sensitive Displacement Transducer 5 to 25 mm
Displacement transducer with bellows mounted on the shaft of a CDP-type displacement transducer. Used for measurements in poor environmental conditions, e.g. on site.
Protection rantings : IP 42 equivalent
- Features
- Excellent environmental resistance
- High sensitivity, high power
-
Specifications
Type Capacity Rated output Sensitivity(×10-6 strain/mm) Non-linearity Temperature range CDP-5B 5mm 5mV/V
(10000×10-6strain)
±0.1%2000 0.15%RO -10~+60℃
(no condensation)CDP-10B 10mm 5mV/V
(10000×10-6strain)
±0.1%1000 0.1%RO CDP-25B 25mm 6.25mV/V
(12500×10-6strain)
±0.1%500 Output polarity
Measurement moves in the minus direction when the shaft is pushed inward.
More Information
CDP-D Displacement Transducer with dual ports 50 to 100mm
The CDP-D displacement transducer is the CDP displacement transducer with dual isolated I/O ports. For example, one set of input and output cables can be connected to an analog measuring instrument and the other set to a digital measuring instrument. With two different types of measuring equipment connected to this transducer, simultaneous measurements can be made without interference.
Protection ratings : IP 40 equivalent
- Features
- Measurement with two readout units
- High precision, High output
- Excellent response
- Easy handling
-
Specifications
Type Capacity Rated output Sensitivity
(×10-6 strain/mm)Non-
linearityTemperature
rangeCDP-50-D 50 mm 5 mV/V
(10000×10-6 strain)
±0.1 %200 0.1 %RO -10 to +60 ℃
(no condensation)CDP-100-D 100 mm 100 Output polarity
Measurement moves in the minus direction when the shaft is pushed inward.
More Information
Pull-out type Displacement Transducer CDP-T 25mm
This is a displacement transducer having a spring force to draw the shaft inward the transducer body. It is based on our well-proven CDP type transducer, but its shaft is fully contracted by the spring force while the shaft of our ordinary CDP transducer is fully extended. A wire is hooked on the hook bolt mounted on the end of the shaft, and the shaft is pulled out by the wire. Displacement is measured as the movement of the shaft. Highly accurate measurement is possible owing to its large output and excellent stability.
(When using a wire for the displacement measurement, consider the loss of sensitivity caused by the elongation of the wire.)
Protection ratings: IP 40 equivalent
- Features
- High accuracy and high output
- Measurement possible in tensile direction
- Easy handling
-
Specifications
Type Capacity Rated output Sensitivity
(×10-6strain/mm)Non-linearity Allowable temperature range CDP-25T 25mm 6.25mV/V
(12500×10-6strain) ±0.15%500 0.15%RO -10~+60°C (no condensation) Output polarity
Measurement moves in the minus direction when the shaft is pushed inward.
More Information